42
External Pressure Transducers
–
Entering Calibration coefficients
External pressure transducers from HWM have
calibration coefficients that must be entered into IDT
in order for Sentinel 2 to use them correctly.
Enter the values, as per the example opposite
(including any negative symbols).
Note: The final number represents the
maximum
pressure range
of the transducer (in bar).
At this stage, it is important that the channel settings stored in the
PC memory should be written into the Sentinel 2.
Scroll to the bottom of the Setup tab and c
lick “Setup Device”
.
(The unit will now operate with the channels as set earlier).
Re-
load the program into IDT by clicking the “Read Device” button.