Troubleshooting
SYSTEM TROUBLESHOOTING
GUIDE
(continued)
Problem
Probable Cause
Solution
System turns off by itself,
no fault condition showing
Loss of power
No action
Program set up to run for a
certain amount of time
Adjust as needed (see control section)
Program set to make a specified
amount of water
Adjust as needed (see control section)
Program set to turn on or
off at specified times
Adjust as needed (see control section)
Low-pressure pump
will not shut off
Isolation relay on main control board is faulty Send to factory for repair
High-pressure pump
will not shut off
Isolation relay on main control board is faulty Send to factory for repair
Brine flow paddle wheel
does not stop spinning
after shutdown
System is in a fresh water flush mode
Wait for fresh water flush to time out
Fresh water flush solenoid valve is faulty
Replace or repair valve
Fresh water flush relay on
control board has failed
Send to factory for repair
System is making good
water but not diverting
to fresh water tank
Quality solenoid has failed
Check wiring / Replace valve (use over ride
button on valve to divert water until repaired)
Quality solenoid relay on
control board has failed
Return control board to factory for repair
Brine flow is too low
High pressure pump seals worn
Replace seals
Product flow is low
System pressure to low
Increase pressure
Feed TDS high
Adjust pressure up to 1000 PSI to
compensate for high TDS
Water temperature low
Adjust pressure up to 1000 PSI to
compensate for low temperature
Membranes are fouled
Clean or replace membranes
System does not
turn on when power
button is pressed
Fuses blown on main control
Replace fuses
Power not on
Apply power
System draws high amperes Low or incorrect voltage applied
Adjust voltage to system specifications
High pressure not
increasing when HP Valve
is turned counter clockwise
HP pump seals need service
Repair high pressure pump
Valve stem worn
Replace high pressure valve
High quality light
does not come on
Pressure too low on system
Increase pressure to rated output
Membrane is fouled
Clean or replace membrane
Probe needs to be cleaned
Clean or replace probe
Table 3: System Troubleshooting Guide (continued)
Summary of Contents for MAX-Q+
Page 1: ......
Page 2: ......
Page 16: ......
Page 22: ......
Page 26: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 62: ......
Page 72: ......
Page 87: ......
Page 108: ......
Page 113: ......
Page 115: ......
Page 117: ......
Page 122: ......
Page 130: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ......
Page 145: ......
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......
Page 160: ......
Page 161: ......
Page 162: ......
Page 163: ......
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......
Page 169: ......