36
Error #611, 612, 613, 614: CO2 or Solution Leak
The barrel pressure is rising during a fill circuit diagnostic test.
1
Determine if the barrel is filling with CO2 or liquid. If the barrel liquid level is low enough use a
flashlight to look at the back of the barrel and see if liquid is entering the barrel. Replace a
leaking solenoid.
2
Ensure the solenoids are not manually turned on by going to the manual on/off menu. Check
to see if either solenoid is receiving power by removing the leads and testing with a volt meter.
If 12 VDC is measured on the CO2 solenoid or 24 VAC is measured on the solution solenoid
then replace the control board.
Error #621, 622, 623, 624: Barrel Leak
The barrel pressure is dropping during a fill circuit diagnostic test.
1
Look for any obvious leaks by searching for liquid along the product line from the solution
module to the back of the barrel.
2
Inspect the rear seal to determine if the leak is originating from it.
3
Inspect the relief valve in the faceplate to determine if the leak is originating from it. Press and
turn the relief valve to firmly seat.
4
Inspect the dispensing nozzle to determine if the leak is originating from it.
Error #630: Refrigeration Pressure Transducer Offset
The pressure transducers were not reading correctly during the refrigeration diagnostic test.
1
Attach a set of refrigeration gauges that are known to be accurate and then compare the
gauges to the readings on the LCD. Replace the pressure transducer that is reading incorrect.
Summary of Contents for 77 Series
Page 1: ...772 773 774 24 2396 0001 Rev C 07 30 2013...
Page 38: ...38 772 Mounting Dimensions 773 Mounting Dimensions...
Page 40: ...40 WIRING SCHEMATIC DIAGRAM...
Page 41: ...41...