32
Error #051, 052, 053, 054: Safety Fill Error
A barrel filled continuously for more than two minutes.
1
Run the fill diagnostic sequence to determine the reason for the failure.
Error #061, 062, 063, 064: Beater Low Error
A beater motor stalled during operation.
1
Check the brix in the barrel. If low, check the brix at the sample valve and adjust if needed.
Drain and refill the barrel.
2
Check the fault code history for multiple sold out errors within a short period. This can mean
that the BIB connector or syrup pump has a suction leak. Fix if necessary.
3
Run the beater circuit diagnostic if a component failure is suspected.
Error #070: Compressor Ran Too Long
The compressor ran continuously for more than 90 minutes.
1
Is the location an extreme volume venue such as a festival? If so, contact FBD service for
instructions on adjusting the timer.
2
Run the refrigeration diagnostic sequence to determine the reason for the failure.
Error #081, 082, 083, 084: High Barrel Pressure
The pressure on a barrel exceeded 55 PSI
1
Dispense a drink to reduce the barrel pressure. The unit will refreeze if set to the ON mode.
2
Run the fill diagnostic if a failed component is suspected.
3
Check the “Active Charge” regulator located on the product header to ensure it is set at
30 PSI. All barrels should be fully depressurized before checking the active charge.
Error #090: Hot Product Detected
The system shut down because product in a barrel exceed 85°F
1
Check the return temperature sensor for proper operation.
2
If hot product was detected, call FBD for technical assistance.
Error #101, 102, 103, 104: Possible Low Brix
There have been multiple low beater errors (error# 06X) within a time period.
1
Check the brix in the barrel. If low, check the brix at the sample valve and adjust if needed.
Drain and refill the barrel.
2
Check the fault code history for multiple sold out errors within a short period. This can mean
that the BIB connector or syrup pump has a suction leak. Fix if necessary.
Error #111, 112, 113, 114: Motor Failure
The beater motor is not operating.
1
Run a beater circuit diagnostic to determine the problem or refer to error #58X in this manual.
2
Check to make sure the beater motor is plugged in.
Error #121, 122, 123, 124: Beater High Error
The control board is not reading the proper value from the beater motor.
1
Run a defrost cycle to reset the motor baseline value.
2
Run a beater circuit diagnostic to determine the problem or refer to error #58X in this manual.
Error #130: Board failure
The control board is not functioning properly.
1
Cycle the power to the unit to see if it will clear the error.
2
Replace the control board.