Maintenance Options Menu
The maintenance menu is for purging, filling and draining the barrels. There are three routines; all of which are
semi-automated and eliminate the need to manually turn solenoids on and off. Follow the on-screen prompts
to complete each process.
• Gas Purge: This procedure is used after the faceplate has been removed and there is air in the barrel.
It will purge the air from the barrel and replace with CO2. Use this process before filling the barrel. The
process will fill the barrel with CO2 three times before automatically ending.
• Drain Barrel: This process will assist in draining a liquid barrel (defrost first if needed). The user must
terminate this process by pressing the END button once the barrel is empty.
• Fill Barrel: This process fills the barrel with product. The user must terminate this process by pressing
the END button once the barrel is full.
All processes may be terminated at any time by pressing the END button.
Settings Menu
The settings menu has several items that are adjustable:
SERIAL#: Set the serial number of the unit. This is used for Bevtrak reporting.
BARRELS: Define the number of barrels for the dispenser.
DISPLAY UNITS: Set the unit of measurement to English or SI.
SYRUP TYPE: Set the syrup type to “FCB” or “Fountain.”
Note:
The unit changes internal settings based
on the syrup type.