Repeat this adjustment procedure an all other cylinders, after
cranking the crankshaft accordingly.
Install the cylinder head cover with a new gasket.
Tightening torque: 13 Nm (10 ft·lbs)
After a short test run check the engine for leaks.
6.10.2
Changing hydraulic oil and breather filter
See also the notes on the hydraulic system in the
chapter "General notes on maintenance".
WARNING!
Danger of scalding!
When draining off hot hydraulic oil!
NOTICE!
The hydraulic oil must also be changed after major
repairs in the hydraulic system.
Perform the oil change when the hydraulic oil is warm.
Replace the hydraulic oil filter elements with every
hydraulic oil change.
Change the filter only after the hydraulic oil change
and after the test run.
Clean the area round hydraulic oil tank, filler opening
and breather filter.
Do not start the engine after draining the hydraulic oil.
Do not use any detergents to clean the system.
Use only lint-free cleaning cloths.
For quality and quantity of oil refer to the "table of fuels
and lubricants".
When changing from mineral oil based hydraulic oil to
an ester based biologically degradable oil, you should
consult the lubrication oil service of the oil manufac-
turer for details.
ENVIRONMENT!
Catch running out hydraulic oil and dispose of environ-
mentally.
Maintenance
BW 213 D-4
139
Summary of Contents for BOMAG BW 213 D-4
Page 2: ...2 ...
Page 6: ...Table of contents BW 213 D 4 6 ...
Page 7: ...1 Foreword Foreword BW 213 D 4 7 ...
Page 10: ...Fig 2 Fig 3 Foreword BW 213 D 4 10 ...
Page 11: ...2 Technical Data Technical Data BW 213 D 4 11 ...
Page 15: ...3 Safety regulations Safety regulations BW 213 D 4 15 ...
Page 29: ...4 Indicators and Controls Indicators and Controls BW 213 D 4 29 ...
Page 30: ...Fig 8 Indicators and Controls BW 213 D 4 30 ...
Page 49: ...4 5 Line diagram EVIB only BTM prof Fig 41 Indicators and Controls BW 213 D 4 49 ...
Page 53: ...5 Operation Operation BW 213 D 4 53 ...
Page 92: ...Operation BW 213 D 4 92 ...
Page 93: ...6 Maintenance Maintenance BW 213 D 4 93 ...
Page 117: ...NOTICE Check the V belt tension after a running time of 30 minutes Maintenance BW 213 D 4 117 ...
Page 153: ...7 Trouble shooting Trouble shooting BW 213 D 4 153 ...
Page 161: ...8 Cab assembly before initial start up Cab assembly before initial start up BW 213 D 4 161 ...
Page 174: ...Cab assembly before initial start up BW 213 D 4 174 ...
Page 175: ...9 Disposal Disposal BW 213 D 4 175 ...
Page 177: ......
Page 178: ......