
6th edition, 22.05.2023
7000.05060, 6th edition, 22.05.2023
7000.05060
Installation
48
4.3.4.1
Establishing the shield connection
The best results when establishing a shield connection on the cable are achieved in the fol
-
lowing way:
Fig. 34: Motor cable shield connection
1. Remove approx. 50-100 mm from the outer cable shield (1). Make certain that none of
the fibers of the braided shield (2) are destroyed.
2. Either push back the shield or roll it up and fasten with heat-shrink tubing (4).
3. Optionally fit crimp-sleeves on the cable ends (5) and attach to the plug connectors.
4. Fasten the shield and the fixed end of the heat-shrink tubing with a cable tie (3).
1
Outer cable shield
2
Braided shield
3
Shield clamp
4
Heat-shrink tubing
5
Crimp-sleeve
1
2
4
5
3