KIC551
K I C 5 5 1 U s e r M a n u a l
58
© 2 0 2 1 F a s t w e l V e r . 0 0 3
Below you can find an example of booting the Program Configuration Unit, placed in the file
“gbs_cfg1.bin” in the root directory to the NAND drive using Telnet connection.
For booting a copy of the Program Configuration Unit from NAND drive you should perform the
following sequence of instructions:
1. Test reading of the EEPROM register contents of multiplexer. 4 most significant bits of this
register always restore 0
хE.
2. Switching the microcontroller to the configuration EEPROM 88E6185.
3. Loading the Program Configuration Unit
“gbs_cfg1.bin” to the configuration EEPROM 88E6185.
In order for the changes to take effect (for the newly written configuration to become active), you
should perform the power supply on/off switching cycle of the KIC551/KIC551RC module.
4.2.4 Booting the Program Configuration Unit of the 10 Gbit Ethernet controller
The Program Configuration Unit of the 10 Gbit Ethernet controller contains the settings of VLSI
parameters of the Intel 82599EN controller: MAC-address, Power Management registers, LED
registers, PHY registers and others.
The working
Program Configuration Unit is stored in the configuration EEPROM AT25256B of the
10 Gbit Ethernet 82599EN controller.
For synthesis of the Program configuration Unit, you can use the “lanconf.exe” utility provided by
Intel for its controllers. Information on the purpose and programming of service registers VLSI
82599EN can be obtained in 82599-10-gbe-controller-datasheet.pdf [4], see Annex G).
Below you can find an example of booting the Program Configuration Unit, located in the
“10gb_cfg.bin” file in the root directory on NAND drive, using the Telnet connection.
For booting a copy of the Program Configuration Unit from NAND drive, you should perform the
following sequence of instructions: