3-50
Frequently Used Functions
Edge Offset ([S7] - [D2], [S7] - [D9])
Edge offset sets the length of time to compare for changes to the received light amount.
Set it as follows together with “Response time”.
• Edge offset: Sets the length of time to compare the present received light amount and the monitored
received light amount.
• Response time: Sets the cycle time (interval) to monitor the received light amount.
Example) With Response time set to 250 µs and Edge offset set to 1250 µs
The received light amount is monitored for the cycle set with Response time (an interval of
250 µs), and then the received light amount from the time set with Edge offset (1250 µs) before is
compared with the present received light amount.
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ ⑪ ⑫ ⑬ ⑭ ⑮
Received light
amount
Time
Edge offset (1250 µs)
Response time (250 µs)
Threshold
Threshold
Comparison target
(Both/Positive)
Comparison target
(Both/Negative)
ON
OFF
ON
OFF
ON
OFF
Output signal
Output signal
Output signal
• Edge direction: “Both”
• Edge direction: “Positive”
• Edge direction: “Negative”
➂→➇
➁→➆
➀→➅
Negative edge: ON
➂→➇
➁→➆
➀→➅
Negative edge: ON
➇→⑬
➆→⑫
➅→⑪
Positive edge: ON
➇→⑬
➆→⑫
➅→⑪
Positive edge: ON
Summary of Contents for D4RF Series
Page 2: ......
Page 12: ......
Page 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Page 16: ...1 4 Part Names...
Page 17: ...2 Installation and Connection This section explains how to install and wire this product...
Page 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Page 82: ...3 58...
Page 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Page 122: ...5 8 Errors and Countermeasures...
Page 137: ......