3-27
1
2
3
Basic Usage
Manual Adjustment of the Threshold
3-5 Manual Adjustment of the
Threshold
The threshold set with the teach function can be changed manually.
Use this operation to make adjustments to the threshold when actual detection is unstable, when the
detection conditions change, and other similar situations.
This operation can also be used to set the threshold directly without executing the teach function.
Operation Procedure
(1 point, 2 points, Auto, and Through modes)
1
On the RUN screen, press
.
A line appears at the bottom of the OLED display,
and the upper section threshold blinks.
2
Press
to change the threshold.
Pressing [+] increases the threshold and pressing
[−] decreases it.
* If no adjustment is necessary, press
TEACH
ESC
to
cancel.
3
Press
MENU
OK
.
The line at the bottom of the OLED display
disappears. This completes the threshold
adjustment.
* Even if
MENU
OK
is not held down, the threshold will be
set to the changed value if approximately 30
seconds elapse, and the OLED display will return
to the RUN screen.
1
2
MENU
OK
TEACH
ESC
100
100
1
2
MENU
OK
TEACH
ESC
100
150
1
2
MENU
OK
TEACH
ESC
100
150
Summary of Contents for D4RF Series
Page 2: ......
Page 12: ......
Page 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Page 16: ...1 4 Part Names...
Page 17: ...2 Installation and Connection This section explains how to install and wire this product...
Page 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Page 82: ...3 58...
Page 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Page 122: ...5 8 Errors and Countermeasures...
Page 137: ......