6-3
1
2
3
4
5
6
Appendix
Specifications
Type
Stand-alone unit
(IO-Link device)
Inter-connection main unit
Inter-connection
expansion unit
Rating
Supply
voltage
SIO mode
12 to 30 VDC ± 10% including
10% ripple (p-p)
12 to 24 VDC ± 10% including
10% ripple (p-p)
Supplied from main unit
(12 to 24 VDC ± 10%
including 10% ripple (p-p))
IO-Link mode 18 to 30 VDC ± 10% including
10% ripple (p-p)
—
Current
consumption
Eco mode:
Off
52 mA (at 12 VDC), 33 mA (at
24 VDC), 29 mA (at 30 VDC)
52 mA (at 12 VDC), 33 mA (at 24 VDC)
Eco mode:
On
43 mA (at 12 VDC), 29 mA (at
24 VDC), 26 mA (at 30 VDC)
43 mA (at 12 VDC), 29 mA (at 24 VDC)
Warm-up time
300 ms
Applicable regulations
EMC
EU EMC directive (2014/30/EU)
UK directive EMC (The Electromagnetic Compatibility Regulations 2016)
Environment
EU RoHS directive (2011/65/EU)
UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012)
China RoHS (MIIT Order No.32)
Applicable standards
EN 60947-5-2
NRTL certification
UL Listed or Recognized Components Proximity Switch Certified for US and Canada.
*3
Company standards
Noise resistance Feilen Level 4 cleared
Protection circuit
Reverse connection protection, Overcurrent protection
Environmental
resistance
Ambient temperature
*1
/
humidity
−25 to 55°C/35 to 85%RH (no freezing or condensation)
Ambient illuminance
Sunlight: 10000 lx or less, incandescent light: 3000 lx or less
Vibration resistance
10 to 55 Hz; Double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions
Shock resistance
Approx. 50 G (500 m/s
2
) 3 times in each of the X, Y, and Z directions
Degree of protection
IP54
Material
Housing, cover: PC
Weight
Cable model: approx. 71 g (including cable), Connector model: approx. 25 g
Included accessories
Mounting bracket, Instruction manual
*1: The load current and operating temperature are limited by the number of connected units (including inter-
connection main unit) as shown in the table below.
Number of connected units
1 unit
2 units
3 to 5 units
6 to 16 units
*4
Max. input current of main unit
152 mA
144 mA
360 mA
1152 mA
No. of control output per unit
1
2
1
2
1
2
1
2
Load current per control output
100 mA
50 mA
20 mA
10 mA
20 mA
10 mA
20 mA
10 mA
Ambient temperature
55°C
55°C
50°C
45°C
*2: Preset loading selectable only on 2-output and 1-input models.
*3: Products in lot number 2235H and later are UL-certified.
*4: When 6 or more units connected and used as UL certified product, use the product under the conditions
shown in the table below.
Number of connected units
6 to 8 units
9 to 16 units
Max. input current of main unit
576 mA
1152 mA
No. of control output per unit
1
2
1
2
Max. load current per output
20 mA
10 mA
20 mA
10 mA
Upper limit of ambient
temperature
45°C
40°C
Summary of Contents for D4RF Series
Page 2: ......
Page 12: ......
Page 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Page 16: ...1 4 Part Names...
Page 17: ...2 Installation and Connection This section explains how to install and wire this product...
Page 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Page 82: ...3 58...
Page 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Page 122: ...5 8 Errors and Countermeasures...
Page 137: ......