6
Warning
Warning
Function
Function
2.4 Cleaning the Acrylic Sheet: Use uwe Cleanser Only!
Always ensure extremely strict hygiene.
After every period of use, the lying surface must be disinfected and cleaned.
uwe cleanser and other cleaning materials must not be sprayed into the eyes. Do not spray them
into naked flames.
Do not drink them.
Keep out of the reach of children.
Use cleaners in accordance with the instructions and observe the manufacturer’s soaking times.
Do not pour or spill liquid over the unit, so that no moisture will penetrate under the covers and
into the electrical equipment.
After every tanning session, clean the acrylic sheets with the uwe cleanser „PICCOBELLO“, or with the „Paletti
Hydrovlies“ tissues. When using the uwe cleanser „PICCOBELLO”, spray it onto the acrylic sheet and let it react for
at least 60 seconds. Always dry it off with a clean cloth.
TECHNICIAN SPECIFICATIONS FOR uwe-PROFESSIONAL USERS
3 INSTALLING THE PROFESSIONAL UNIT
The unit must be installed only by personnel of the uwe company or by authorised persons. To install
the unit, at least two persons are needed. The rooms in which the units are to be installed must be
well ventilated (adequate air inflow and outflow); otherwise there is a risk of overheating!
All plug-in connections are encoded.
3.1 Place of installation and condition of delivery
•
The whole unit is being transported and delivered on a pallet. Various individual parts of the unit are packed
in cardboards and tied up safely with assembly belts onto the pallet. The pallet with the unit will be unloaded
by a hydraulic ramp or fork-lift truck at the place of destination. In order to install the unit on the planned place
of installation, it will have to be partly dismantled on the pallet and be re-assembled again on the planned
place of installation. All units are exclusively destined for sunbathing in the inside area of buildings. The unit is
only al lowed to be operated in areas where there is no danger of explosion and in dry rooms. The rooms have
to be well ventilated (adequate air inflow and outflow).
3.2 Installation and assembly
•
Disassemble parts of the unit on the pallet
Untie the assembly lines and carry the individual parts (tanning arms, covering hood, tripod) packed in card-
boards to the planned place of installation. Now there still remain the lounger and the footrack assembled on
the pallet. The Plexiglas plate lounger (1, picture 4) lies free on top of the pipeframe (2). Lift down the Plexiglas
plate together with someone. If the pipeframe is fastened together with the tripod, unwind the screws and
then take down the pipeframe (2) as well. Untie both covering plates (3 and 4, picture 3) from the parts of the
footrack. Check up, if all plug-in connections are removed and then pull the assembly plates out of the guide
bar. Then lift the light case (6, picture 2), it is only hung up onto the footrack with two shankscrews (13). Further
on, remove the hexagonal nuts M 8 (7) and toothed disks (8) between both footrack parts. Now you can carry
both footrack parts separately to the place of installation.
•
Assemble the footrack (picture 2)
Place the unit according to the sizes of your place of installation. The unit is shaped preferably for a diagonal
corner installation. Organize both parts (9 and 10) of the footrack according to picture 2. Connect these by
introducing the four M 8 screws (11) welded into the front footrack into the reliefs of the back part of the
footrack and by securing the screws with one toothed disk A 8,4 (8) and one hexagonal nut M 8 (7) each. Then
put the lightcase onto the footrack, so that the shankscrews (13) emerge into the drill-holes (14) of the
footrack designed for this purpose and the connecting cables (15 and 16) emerge into the back part of the
footrack. Check up, if the cable (5) of the illumination light is jammed onto the unit’s terminal (17). Push the
assembly plate lounger (19) right backwards into the middle guide bar, the assembly plate control unit (20)
into the upper guide bar of the back part of the footrack (19) as far as it will go. Then arm the front part of the
footrack by pushing the assembly plate upper arm (21) into the upper guide bar -and the assembly plate arm
right/left (22) into the lower guide bar- of the front part of the footrack (9) as far as it will go.
All the plug-in connections of the unit are encoded.
Take the 9-poled cable X8 (24) and the 18-poled cable X9 (23) of the assembly plate lounger and connect
these together with the connecting cables (15 and 16) of the lighting case (6), which have been previously
pulled through. Put the plugs X8a and X9a of the lighting case together with the corresponding socket
connectors X8a and X9a of the BreakSafe Control (105) on the Control Board.
Put the 18-poled cable X4 (25) of the assembly plate lounger together with the corresponding socket connector
X4 (26) of the assembly plate control unit.
The plug-in connections are numbered. Place the same numbers together.