3.3 Connecting the Unit’s Air Outlet

Attention! Important Information!

On using the SunBoard XTT unit you really must draw oft the already warmed up cooling air through

a direct air removal.

uwe recommends as standard connexion a special adapter part (59), which you can obtain from

uwe.

Accessorial adapter part (59, picture 4)

Fix the adapter part with 4 screws 4,2 x 9,5. Choose the side, into which direction (to the sides or upwards) you want

to draw off the air. There you have to unscrew the closed covering plate (60) and fix at that place the covering

plate (61) with the pipe-connecting piece. All the remaining sides of the adapter part must be closed. In case that

the digging through the wall can’t be positioned directly behind the pipe-connecting piece, then the distance

can easily be bridged over with an air tube (diameter 300 mm). Fix the tube for used air on the pipe-connecting

piece with a tube clip. Carry the tube for used air by means of tube connecting pieces, wall case and automatic

exterior top flap into the open air, or connect it onto a ventilation shaft. You can obtain these parts with a

diameter of 300 mm at your specialized store or at uwe.

Attention, important information! You must observe this; otherwise there is a danger of over heating!
To avoid excessive resistance to the air flow, the hose should not be longer than 6 m and should be

laid so that any bends have as large a radius of curvature as possible, and without any kinks. If the

air is discharged to the outside via a ventilation duct, it must be ensured that the flow resistance in

the interior of the duct is as low as possible; if necessary, an additional fan might need to be

installed there. In this case, please consult a ventilation engineer.

The rate of air discharge is about 2200 m

3

/hour; accordingly, fresh air must be allowed to enter the

cubicle at the same rate. Therefore, you must provide fresh air openings in the wall of the cubicle,

having an unobstructed cross-section of at least 1000 cm

2

.

Further information on effective ventilation can be found in the brochure „AIR-CONDITIONING TIPS“

which is available from your dealer or from us.

3.4 Electrical Connection

Important:
The connection work may only be done by an electrical expert in accordance with the applicable

 regulations.
The person installing the unit must carry through an inspection and make a report on it.

Operating Voltage: 3PE~60 Hz 220 V 50 A.

An isolation switch (plug, main switch, fuses, Fl circuit breaker) is to be provided in this line with which the unit can

be completely (all poles) separated from the mains power supply. The circuit diagram belonging to each unit is

attached separately to the respective unit.

Attention!

In case of connection over a Fl circuit breaker it has to be observed, that during the process of ignition there occur

derivating current points, which are so short-termed, that they can only be detected by an oscillograph. If various

units are operated together with one Fl circuit breaker, when switching on the units simultaneously, the points may

add and lead to release the Fl circuit breaker, without there being any defect on the unit.

Therefore never connect more than 1 unit over one Fl circuit breaker £ 30 mA.

3.5 Coin Operation or Central Control (Figure 2)

Coded Plug for Connection to the Coin Switch and Central Controller (Figure 2)

Plug the coded plug (62) with cable into the special plug with circlip (63). This cable forms the connection bet-

ween the coin box and the central controller. The cable has 4 cores (phase, switched phase, neutral, PE). The coin

box does not therefore need a separate mains power supply connection. The switches in the coin box and in the

central controller must be capable of being loaded to 16 A inductive.

Setting the Coin-Operation Time Switch

The unit may only be connected by a qualified electrician.

Information on operating and setting the unit can be found in the coin meter operating instructions.

For safety reasons, ensure that the maximum tanning session with this unit is limited to 15 minutes.

If you press the red emergency button of the Coin Meter, both the digital display and the high pressure bulbs are

extinguished. The only way to restart the unit is to insert coins again. (Restart of the burner only after approx. 4

minutes).

Summary of Contents for SunBoard XTT

Page 1: ...1 INDOOR TANNING EQUIPMENT CARE USE AND INSTALLATION INSTRUCTIONS Model SunBoard XTT PC MARKETING 1040 WILT AVENUE RIDGEFIELD NJ 07657 1 800 FAST TAN...

Page 2: ...4 1 5 Product Liability 4 1 6 Emergency Procedure 4 1 7 Explanation of Danger Symbols 4 2 OPERATION I INFORMATION FOR THE USER OF THE UNIT 5 6 2 1 Starting to sunbathe 5 2 2 Important Technical Detai...

Page 3: ...week onward USE PROTECTIVE EYEWEAR WHENEVER THE EQUIPMENT IS ENERGIZED READ THE INSTRUCTION BOOKLET BEFORE USING THIS PRODUCT WARNING If you have been diagnosed by a physician as being allergic to th...

Page 4: ...TE AND ARE DESIGNED FOR USE WITH INDOOR TANNING EQUIPMENT FAILURE TO COMPLY WITH RECOMMENDATIONS AND WARNINGS STATED ABOVE MAY VOID THE MANUFACTURER S WARRANTY WARNING THIS UNIT MUST NOT BE USED IF TH...

Page 5: ...ilter disc when exchanging the burner the electrical circuit will be interrupted and the unit can not be started see Section 8 BreakSafe Speakers 34 picture 3 There are two speakers so that you can en...

Page 6: ...on the pallet The Plexiglas plate lounger 1 picture 4 lies free on top of the pipeframe 2 Lift down the Plexiglas plate together with someone If the pipeframe is fastened together with the tripod unwi...

Page 7: ...the tripod Secure the screws 28 of the foot casing with toothed disks A8 4 29 and octagonal nuts M8 30 secure the screws 31 of the light casing with washers 32 having 25 mm in external diameter and w...

Page 8: ...the support 44 of the covering hood 40 After this secure coming from the tripod the four pins 64 with disks 46 having an external diameter of 25mm and with hexagonal nuts 45 You really must tighten u...

Page 9: ...the right side of the tripod This tanning arm has an 18 poled cable X6 53 with plug and the BreakSafe cable X6a these cables you have to pull through down wards into the footrack The plug X6 53 will...

Page 10: ...to the tripod Then arrange the three covering hoods 56 57 58 around the pipeframe The two covering hoods 56 and 58 arranged on the sides of the pipeframe will be fixed onto the tripod by a strip faste...

Page 11: ...ffective ventilation can be found in the brochure AIR CONDITIONING TIPS which is available from your dealer or from us 3 4 Electrical Connection Important The connection work may only be done by an el...

Page 12: ...e even We reserve the right to make technical changes LAMP CONFIGURATION If the lamps are not placed in the correct position this may result in a loss of performance and lifetime Please ensure to use...

Page 13: ...ents Provide protective glasses and ensure that they are used Highlight the need to adjust the length of the sunbathing period depending on skin type Keep user instructions at hand Put up the safety i...

Page 14: ...n the acrylic sheet with important information Please note the information and then remove the sticker Do not operate units without acrylic sheets because otherwise the cooling of the lamps is no long...

Page 15: ...int on both sides Pull off the disk holder from the front using both hands Hold the high pressure lamp by the rectangular base and press it out of the socket Cleaning the Reflector Clean the reflector...

Page 16: ...ng the High Pressure lamp Hold the new high pressure lamp by the base 102 Insert the lamp into the holder 77 Attention The contact pins 79 of the socket have different diameters Please insert accordin...

Page 17: ...ilter so that it is only necessary to clean the components inside the unit e g such as filter plates infrequently The particles filtered out eventually clog the filter after extended use and thus redu...

Page 18: ...k holder 75 picture 7 and the reflector 87 If this does not help there is an electrical defect in the unit Checking up by uwe or by another firm named by uwe The illumination light does not shine exch...

Page 19: ...ses They should not be thrown together with the regular waste The local offices will inform you where the burner could be properly wasted Unit Faulty units should be disposed of according to local reg...

Page 20: ...20 ID NR 265 360 03 03 PC MARKETING 1040 WILT AVENUE RIDGEFIELD NJ 07657 1 800 FAST TAN...