5
•
If a hydraulic system leak is found, stop the system immediately and
rectify the fault.
•
Note that due to operation, the oil may be 70 degrees Celsius or even
hotter. This can lead to a risk of scalding during separation of the
hydraulic system.
•
IMPORTANT: Maximum battery charging power is 2 amps. Charging
more than 2 amps may cause the battery to crack. The battery must be
charged at a temperature between 0 °C and +40 °C. Never place the
battery in a sealed container while charging. During winter, the battery
must be removed and stored in a dry place indoors in a fully charged
state.
•
Avoid sparks and flames on and around the battery.
•
Do not short circuit the battery.
•
Never disassemble the battery.
•
If you come into contact with the battery's sulphuric acid, wash
immediately with water. If acid comes into contact with eyes, rinse
thoroughly with water and seek medical attention immediately.
•
Pay attention to the battery compartment. If there are cracks,
deformities, electrolyte leakage, etc., replace the battery immediately.
•
If the battery is dirty, clean it immediately.
•
Disposal of oil spills: - If oil spills are found, they should be cleaned up
immediately with rags or oil absorbent powder. - Spilled products, as
well as rags and powder used for oil spills, must be stored in sealed metal
containers and delivered to the municipal collection site.
•
Hoses, tyres and other parts of the irrigation machine must be disposed
of at an approved recycling site.
If the machine is to be moved via public roads, it must first be drained of
water.