17
Standard menu:
Standard display
SPEED
ZONE
DOSE
TIME
STOP
STATUS
Speed. Can be changed at any time during irrigation using the "+" and "-" keys.
Current zone 1...4, with corresponding speed. The speed cannot be changed. (Zone active)
The dose is calculated from the speed and constants and shows the current number of mm for irrigation. As
SPEED increases, DOSE decreases. (Constants 11 and 12)
To set the time: Set SPEED to 11.1 m/h and press the
PROG
key 3 + 1 times until the display shows <CONST 1 TIME>.
The time can then be set with the "+" and "-" keys. When the battery has been disconnected, the clock will show 0:00 until it is
set again.
The time that irrigation is completed, incl. pre- and post-irrigation. If the clock is not set and shows 0:00, the
total irrigation time is displayed.
Irrigation status, e.g.:
<
Stop sensor
>
<
Irrigating
>
<
Pre-irrigating
>
<
Post-irrigating
>
<
LOW pressure
>
See explanation in STATUS chapter.
If the display shows:
LOW BATTERY
instead of SPEED, the battery voltage is below 11.8 V and the battery needs to be charged.
DISTANCE
BATTERY
CHARGER ON
PRE
POST
Length of the unwound hose. The length can be changed immediately after pressing the
PROG
key 3 times, using
the "+" and "-" keys.
Battery voltage.
Shows when the battery is being charged by a solar cell. The battery is charged when the voltage is below 14.0
volts.
Shows the pre-irrigation time.
Shows the post-irrigation time.
The pre- and post-irrigation times can be changed immediately after pressing the
PRE-
or
POST-
keys, using the
"+" and "-" keys.