MACHINE DATA
Machine data
number
Flashing digit
Possible setting
Factory setting
0
Hose length
0 - 1,000m
Not used
1
Hose diameter
40 - 200 mm
110
2
Hose drum int. Diameter
500 - 3000 mm
Not used
3
Number of hose turns per layer
5.00 - 30.00
15
4
Large gear on hose drum
50 - 1000
Not used
5
Small gear on gearbox
5 - 40
Not used
6
Number of magnets
1 - 20
Not used
7
Ovality compared to 100 %
0.70 - 1.00
0.85
8
Length of first pulse to stop valve
0 - 45 sec.
3
9
Length of subsequent short pulses to stop valve
0 - 300 m/sec.
160
10
Time between short pulses to stop valve
1 - 5 sec.
2
11
Number of short pulses to stop valve
0 - 250
100
12
Mechanical stop (with only 1 motor)
Electrical stop
(closed low pressure) even if the pressostat registers low pressure
0
1
1
13
Length of pulse to regulator motor at start-up
(Oil pump Motor 1)
26.1 - 0.9 sec.
4.5
14
Pressostat not connected
Pressostat connected (to start/stop) or Radio start
Pressostat installed: (can be used (for start only)
for 2 machines on the same system, Autostart with special pressostat.)
0
1
2
1
15
Length machine moves per pulse: 0 = Moves according to formula
FM4300 & FM4300H = 73.5 mm (2 magnets)
FM4300 & FM4300H = 38.8 mm (4 magnets)
FM4400 & FM4400H = 46.2 mm (4 magnets) Old Rear axle assembly
FM4400 & FM4400H = 46.0 mm (4 magnets) New Rear axle assembly
FM4500 & FM4500H = 85.0 mm (2 magnets)
FM4500 & FM4500H = 42.5 mm (4 magnets)
FM4550 & FM4550H = 46.2 mm (4 magnets) Old Rear axle assembly
FM4550 & FM4550H = 46.0 mm (4 magnets) New Rear axle assembly
FM4800H = 43.3 mm (4 magnets) Old Rear axle assembly
FM4800H = 46.0 mm (4 magnets) New Rear axle assembly
FM4900H = 103.0 mm (2 magnets)
FM4900H = 51.5 mm (4 magnets)
FM4900H = 46.8 mm (4 magnets) New Rear axle assembly
FM5500H = 47.0 mm (4 magnets)
FM5500H = 47.0 mm (4 magnets) New Rear axle assembly
62.5 = When moving with roller Ø80 [mm]
0 = Moves according to formula (with data number 0 to 7)
0 - 160.0 mm
16
Speed sensor
0 = Round sensor for roller
1 = Double sensor
0
1
1
17
Opening of inlet valve
0 = Quick opening
1 = Slow opening
0
1
0
18
Pressostat
0 = Inlet remains open at low pressure
1 = inlet closes at low pressure
0
1
0
19
Delay from stop sensor to turbine stopping (sec)
0
0