23
There are a variety of constants that can be modified by the user.
These constants will be stored for many years, even if the battery is removed.
Programming procedure:
Adjust the speed to 11.1 m/h to access the constants.
Press the
PROG
key 3 times in quick succession to access and change the constants.
Press the
PROG
key again to count forward to the constant you wish to change.
Press "+" and "-" to adjust the value of the constant.
Press the
MENU
key to save the change and the display will return to normal.
If the
MENU
key is not pressed, the display will return to normal after 1 minute and the change will not be saved.
CONSTANTS
Cons
no.
Note
Fact.
Adj.
Min.
Value
Max.
Value
Description
0
100
-
-
Enter 111 to reach machine data
1
00:00
00:00
23:59
Time in line 2 is set
2
8
1
15
Pre irrigation
3
8
1
15
Pre irrigation
4
20
0
99
Supervision time [minutes]
5
1
1
15
1 English, 2 Danish, 3 German, 4 French, 5, Dutch
6 Swedish, 7 Spanish, 8 Italian, 9 Polish, 10 Japanese
11 Hungarian
6
0
0
2
0 = Stop for high pressure slow shutdown
1 = Stop for low pressure. valve opens and close again after 3 minutes
2 = Motor for stop disconnected
7
-
0
1000
Actual distance, can be set by the keyboard [m]
8
0
0
1000
Early stop [m]
( * Is only performed when Post Irrigation is selected * )
9
0
0
1000
Post irrigation before stop [m]
10
0
0
1000
Distance for alarm [m]
( * Disabled if Machine data 22. Sprinkler, is selected * )
11
40
5
120
Water flow [m3/h]
12
60
5
100
Spacing between irrigation lanes [m]
Set Constant no. 0 to 111 to set the machine data.
Then press
PROG
to display the machine data.