LUBRICATION & MAINTENANCE
LUBRICATION & MAINTENANCE Utility Sprayer 25' / 30' / 40' / 45'
Page 83
Pump Maintenance and Service
Filter
The filter location varies by operating
system. There may be more than one filter.
Follow the procedure below for each filter.
IMPORTANT: Loosen and tighten the
filter bodies by hand. Do not use a
wrench as this could damage the filter
body.
At the start of each day before the water and
chemicals have been added, the screens
should be checked and cleaned.
1.
Close the tank valve and agitation
valve.
2.
Place a pail under the filter. Remove
the drain plug(s) and allow all liquid to
drain.
3.
Turn the filter body to remove it.
4.
Remove the screens and inspect
them for dirt or damage.
5.
Clean the screens using clean fresh
water.
6.
Inspect the screens for holes or tears.
If any screen is damaged, replace it.