Page 14
Use and Maintenance Manual - Spare Parts
Completely fill the hydraulic control unit tank with oil. The
rest should be poured in after carrying out the operations in point 14.
13) Press the up button to allow the oil to flow inside the cylinders.
During this operation, only the trolley on the commands column will go up.
Once high, continue to keep the up button pressed to move
the other trolley up.
ATTENTION! Check nothing can interfere with trolley sliding.
When the second trolley has also reached the high position, continue to keep
the up button pressed for 10/15 seconds to complete filling of the hydraulic
circuit.
14) Assemble the cable (11) to check trolley height difference. The cable is in
the column (5) and must follow the path as displayed in the Fig. passing
inside the risers (15) and the beam (16), using the pulleys (12) to change
direction. Block the cable on the terminal (13) found in the column (4) in
such a manner that the micron castor (14) is at the centre of the cam that is
positioned on the lower part of the column (5) as indicated in the figure.
Fig. 4
– Cable assembly
ATTENTION! The lift locks if there is a height difference between the
trolleys during the down phase and normal functioning. To level the
trolleys again, move them up to the end stroke and continue to keep the
button pressed for 5 seconds. These operations can also be carried out
with a load. You are advised to carry out this levelling operation each time
the trolleys are in the high position
.
A
Summary of Contents for FZ63/3S
Page 2: ......
Page 32: ...Page 32 Use and Maintenance Manual Spare Parts THREE PHASE ELECTRIC DIAGRAM...
Page 33: ...Use and Maintenance Manual Spare Parts Page 33...
Page 35: ...Use and Maintenance Manual Spare Parts Page 35 SINGLE PHASE ELECTRIC DIAGRAM...
Page 36: ...Page 36 Use and Maintenance Manual Spare Parts...