Manual
EXCELENT Premium 6; 8
30
│
52
4.5.2
Setting Acoustic Signal
This signal can be set for the level of the hopper and blockage of the rail line. The signal can be set
individually for each function. To turn on or off, press the button and a cross will appear on the icon of the
speaker (the function is off).
Picture 43 – Setting acoustic signal
4.5.3
Setting the Number of Sensors and Change in Address
This setting is preset by the producer. It depends on the type of machine and it does not have to be
adjusted during regular operation. The value is only adjusted when a sensor is replaced by a new one.
Press the button for setting sensors and adjust the number by pressing plus or minus. A red line will
appear below the number of the sensor to indicate editing. When you are done, press the button for setting
sensors again to leave the menu.
Picture 44 – Setting acoustic signal
4.5.4
Replacement of the Sowing Sensor and New Sensor Number Assignment
When replacing a faulty sensor, the new sensor needs to be set with the proper number (original). Be very
careful when performing this task so that you do not delete the addresses of all sensors. You must observe
the following procedure:
1.
Disconnect and replace the faulty sensor in the hopper
2.
Connect the sensor to the connecting cable from module 2 which is under the distributor.
Make sure that only this sensor is connected!
3.
Set the number on the unit by one value higher than the required number of the sensor
4.
Press the button for deleting the numbers of sensors and then the button for deleting "C"
5.
The module must beep after you press this button. The sensor is deleted!
6.
Press the button again to leave the menu
7.
Press again the button for deleting "C"
8.
Disconnect the new sensor
9.
Set the required number of the sensor on the button for sensor numbers and leave editing
10.
Then connect the sensor – the module must beep
11.
Turn off the whole electronic system
12.
Disconnect the sensor
13.
Connect all sensors as they were originally
14.
Turn on the electronic system
15.
Set the original total number of sensors
16.
Leave display 2
17.
Re-addressing is completed