LIQUID-FOOT PRO SERIES MIDI FOOT CONTROLLER
Turning the Power On
Once all non-power related cables and connections are properly installed , you can connect the
power adaptor to the power input jack. Turn the Power Switch to the On position and the unit
will begin its turn-on sequence.
Notes:
If a Firmware revision was being updated and had not properly completed its process prior to powering
off, the firmwar[Type a quote from the document or the summary of an interesting point. You can
position the text box anywhere in the document. Use the Text Box Tools tab to change the formatting of
the pull quote text box.]
1.
The system will automatically begin to load the firmware again. Firmware must properly update
the system during this process. The unit will automatically restart upon successful completion.
Any failures to update will require technical servicing.
2.
The unit will begin by showing the current product name and current firmware version.
3.
The LED (lights) on the unit will pulse on and off for every button (Except the MENU button
which doesn’t have an LED). Please insure that the UP/DOWN keys display Amber. Buttons P1-
P6 display Blue. Buttons S1-S16 alternate Red and Green. The TEMPO/2
nd
Function should blink
Green. This test will allow you to insure all LEDS are in working order. Various other tests are
being performed. Should you receive an ERROR message, Please contact technical support.
Overrides are available at startup to modify normal startup behavior. When using an override,
press and hold one of the indicated buttons below and then turn on the power. Hold the desired
bypass button until the device passes the startup tests:
1.
MENU + Power On
will allow you to erase all of the memory.
2.
P1 + Power On
to force PRESET MODE (Default mode)
3.
P2 + Power On
to force SONG MODE (Starts in Song Mode)
4.
P3 + Power On
to force SETLIST MODE (Starts in SetList Mode)
5.
S1 + Power On
Do not process last known state on power up
6.
S2 + Power On
Preset Bypass Mode. Start device and DO NOT automatically
go to last used patch. Will load patch 0.
7.
S13 + Power On
Special Utility Processing (will detect what needs processing).
8.
S15 + Power On
Normal-Power-on w/override (troubleshoot mode)
9.
S4 + Power On
MIDI/Firmware Load (troubleshoot mode)