31
Technical Data
This cooker is category II2E3+
It is supplied set for group H natural gas.
A conversion kit for other gases is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
See appliance data badge for test pressures
Gas
Electric
Natural Gas
20 mbar
220 - 240V 50Hz
Propane
37 mbar
Butane
29 mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 915 mm
maximum 942 mm
Overall width
1090 mm See ‘Positioning of Cooker’
Overall depth
660 mm (600mm excluding handles)
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
800mm
Connections
Gas:
Electric
Rp 1/2 at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Hotplate
Input
Injector
Input
Injector
Centre Burner
5.0 kW
165
5 kW (357g/h)
107
Large Burners
3.0 kW
120
3.0 kW (214g/h)
82
Right hand front Burner
1.7 kW
95
1.7 kW (121g/h)
64
Gas burner inputs based on Gross Calorifi c Value
Ovens
Left hand Multifunction Oven
Right hand Fan Oven
Fan element
2.5 kW
2.5 kW
Top element
1.2 kW
Browning Element
1.15 kW
Bottom element
1.0 kW
Ovens
Multifunction
Forced air convection
Energy effi
ciency class :
on a scale of A (more effi
cient) to G (less effi
cient)
B
A
Energy consumption based on standard load
0.90 kWh
0.85 kWh
Usable volume (litres)
62
67
Size
Medium
Large
Time to cook standard load
41 minutes
38 minutes
Baking area
1400 cm2
1400 cm2
Maximum total electrical load at 230V 5.1kW approximate total including, oven fan etc.