view from the rear
A appliance gas inlet
B position for gas supply connector or alternativley connect from the
side.
C electrical terminal cover
Because the height of the cooker can be adjusted and
each connection is diff erent it is diffi
cult to give precise
dimensions. Ideally the house supply connection should be in
the shaded area shown in the fi gure showing the back of the
cooker (‘A’ in the fi gure). Alternatively connect from the side.
After completing the gas connection, check the cooker is gas
sound with a pressure test. When checking for gas leaks do
not use washing up liquid - this can corrode. Use a product
specifi cally manufactured for leak detection.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
Pressure testing
The gas pressure can be measured at the pressure test point
on the gas connection block. Turn and light one of the
hotplate burners.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Electrical Connection
This appliance must be installed by a qual i fi ed electrician
to comply with the relevant In sti tute of Electrical Engineers
(I.E.E.) regulations and also the local elec tric i ty supply
company re quire ments.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the cor rect electrical
supply as stated on the voltage la bel on the cooker, through
a suitable cooker control unit incorporating a double pole
switch having a contact separation of at least 3mm in all
poles. This cooker must not be connected to an ordinary
domestic power point.
The total electrical load of this appliance is 8.8 kW at 230VAC
It must be connected to an electrical supply, either single
phase or multi phase that can sustain a maximum current
fl ow of at least 38.3 amps. (Unless local regulations allow this
loading to be reduced by applying diversity factors).
3 phase supplies
Because of the phase loadings it should not be installed on
a 3 phase plus neutral (3N) 16A maximum per phase supply.
For multi phase connections it should only be installed on
3 phase plus neutral (3N) with a capacity of 25A per phase
supply.
It is wired so that the maximum loading on each phase is
approximately: -
Phase 1
11.3 amp
Phase 2
10 amp
Phase 3
17 amp
Access to the mains terminal is gained by re mov ing the
electrical terminal cover on the back panel. When preparing
the electrical supply leads, make sure that the earth wire is
longer that the phase or neutral wires. The earth lead should
be long enough that it is never under any strain.
Connect the mains cable to the correct terminals for your
electrical sup ply type (see fi g.). Check that the links are
correctly fi tted and that the terminal screws are tight.
Secure the mains cable us ing the cable clamp.
These appliances are of type X with regard to protection
against over heating of the sur round ing surfaces.