background image

User manual of ZWP15 controller 

Contents

 1.Description..........................................................................................................................................................2

 2.Installation of ZWP15 controller.........................................................................................................................3

 3.Controller programming  ....................................................................................................................................4

 3.1.Adding device to network (INCLUDE function)........................................................................................5

 3.2.Associating device with a pair of buttons on the controller (ASSOCIATE function)................................6

 3.3.Associating another controller with the network (LEARN MODE)...........................................................7

 3.4.Deleting device from a pair of controller buttons on the controller (DELETE function)...........................8

 3.5.Excluding device from the network (EXCLUDE function)........................................................................9

 3.6.Restoring default settings in the controller (DEFAULT function)............................................................10

 3.7.Removing SECONDARY controller from the network ...........................................................................10

 3.8.Special function ASSAIN A ROUTE........................................................................................................11

 4.Technical parameters ........................................................................................................................................11

 5.Remote control..................................................................................................................................................12

 6.Battery replacement ..........................................................................................................................................13

 7.Warranty............................................................................................................................................................14

12.06.01 NC811-GB

1/16

©2012, 

FAKRO

GB

Summary of Contents for ZWP15

Page 1: ...er controller with the network LEARN MODE 7 3 4 Deleting device from a pair of controller buttons on the controller DELETE function 8 3 5 Excluding device from the network EXCLUDE function 9 3 6 Resto...

Page 2: ...s signalized by all 4 LEDs The ZWP15 controller is equipped with a two way Z Wave radio communication radio module For communication the Z Wave module exploits radio wave frequency of 868 42 MHz In Fi...

Page 3: ...g element by means of two screws driven into cylindrical plugs inserted into openings drilled in the wall 1 Screw the bottom section of the holder to the wall using the included screws which are drive...

Page 4: ...rom the network 3 5 Appropriate implementation of procedures aims to provide optimal communication between devices Disconnecting the device without deleting it from the controller s memory will result...

Page 5: ...twork It is necessary to use EXCLUDE function and repeat the procedure of device adding to the network 12 06 01 NC811 GB 5 16 2012 FAKRO Figure 2 Adding device to Z Wave network 5 Programming error tw...

Page 6: ...ice and repeat INCLUDE and ASSOCIATE functions 12 06 01 NC811 GB 6 16 2012 FAKRO Figure 3 Device associating with selected pair of buttons on controller 3 The controller is signilizing readiness for a...

Page 7: ...ntroller already belonging to another network It is necessary to perform DEFAULT procedure with it and repeat associating with the network 12 06 01 NC811 GB 7 16 2012 FAKRO Figure 4 Associating anothe...

Page 8: ...8 16 2012 FAKRO Fig 5 Deleting device from a pair of buttons on the controllers 4 Press P button on the device and hold it for 0 5 sec see Device Programming Manual 2 Within 1 5 sec press In Ex 1 but...

Page 9: ...leting from the controller s memory is not possible it is recommended to re configurate the whole network all devices Configuration of the new network begins with restoring the controller to factory s...

Page 10: ...from the network Removing this controller from the network consists in restoring default settings with the use of DEFAULT function 12 06 01 NC811 GB 10 16 2012 FAKRO Figure 7 Restoring default settin...

Page 11: ...signalling the error by the controller or resetting it by removing the batteries Note Information on how to call up the function ASSAIN A ROUTE by the use of devices of other manufacturers will be fou...

Page 12: ...ly open Start to close in ZWP ZWK controllers is activated after longer more than 0 5 sec holding of close button and causes the accessory launching into the closing direction until releasing of close...

Page 13: ...oning for the period of 2 years assuming that the programming procedure has been performed only once Multiple device programming shortens the battery life 1 Remove the back section of the casing 2 Rep...

Page 14: ...intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper u...

Page 15: ...12 06 01 NC811 GB 15 16 2012 FAKRO...

Page 16: ...FAKRO PP Sp z o o ul W gierska 144A 33 300 Nowy S cz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 12 06 01 NC811 GB 16 16 2012 FAKRO...

Reviews: