____________________________________________________________________________
- 37 -
Running sequence file
1. Press
to enter test function selecting page;
2.
Rotate the rotary knob to select “Sequence”, press
to activate sequence test, the screen will displays:
80V/510A/15000W
SEQ
0.0000
V
0.0000
A
Step:
0
Cycle:
0
Run file
1
Off
Figure 3-14 Sequence Test Display
3. Set “Run File”, press
to validate it;
4. Press
to start sequence test.
About the display information: “Step:” shows the current sequence step, “Cycle:” shows how many cycles the
sequence have run.
3.13 Internal Resistance Simulation (RESI)
Since a battery has internal resistance, its output voltage will decrease along with the increasing output current.
FTP9000 series power supply provides internal resistance simulation feature to imitate the output characteristics
of batteries. With this function, the power supply output voltage satisfy below formula:
V
o
: Actual output voltage;
V
s
: Theoretical output voltage;
I
o
: Output current;
R
Inner
: simulated Inner resistance.
Operation:
1. Press
to enter test modes selection interface;
2. Use “Rotary”
knob to select “RESI”, press
, the screen displays as below: