3.7.3 Voltage, Current Monitoring Output
FTP9000 series power supply provides analog monitoring output function for its output voltage and current, with
a speed up to 1000 points per second. Power supply 0 ~ 100%F.S. output voltage/current corresponds to 0 ~
5VDC monitoring output, this function is valid once the power supply is powered on.
Figure 3-10 Voltage, Current Analog Monitoring Connection
Figure 3-11 Output Voltage, Current And Monitoring Output
3.7.4 Output Mode & Status Monitoring
The FTP9000 series power supply has an output mode signal port and a fault indication signal port. The port
outputs a 5V TTL level signal, and its functions are as follows:
Output mode signal port
, low level indicates that the power supply is working in CV mode, and high level
indicates that the power supply is working in CC or CP mode;
Fault indication signal port
, low level indicates that the power supply is working normally, high level indicates
that the power supply is abnormal, or protection has occurred but not cleared.
For specific please refer “Table 2-4 Analog Interface Function Explanation”.