FTP9000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 22 -
3. Function Introduction
This chapter describes the main functions and characteristics of the power supply. Reading this chapter, you will
have a deeper understanding of FTP9000 series power supplies.
3.1 Local & remote operation mode
The power supply provides two operation modes: local operation and remote operation. In the local operation
mode, the user mainly operates through the keyboard and knob on the front panel, and checks the power status
through the LCD display; in the remote operation mode, the user mainly performs settings and operations via the
communication interface and programming commands.
Local operation mode
When the power supply is turned on, it operates in local operation mode by default. In this mode, the user
operates the power supply through the front panel keyboard. The LCD screen provides users with display
functions such as parameter viewing, measurement display and status indication.
Some parameters can only be set in local mode, including:
* System language
* Serial port baud rate and parity method
* Key sound
* IP address and subnet mask
* Communication protocol selection
Remote operation mode
To enter the remote operation mode, please use the proper communication cable to connect the PC with the
power supply. The communication configuration parameters must be consistent with the control device settings.
Upon receiving the programming command, the power supply automatically switches to the remote operation
mode from local control mode.
In remote control mode, the power supply can only be controlled by programming commands. Press “Enter” to
return to local operation mode.
3.2 Menu Layout
3.2.1 Set Menu
Press
to enter main menu, then select “Set” and press
to pop up sub menu as below:
Table 3-1 Set Menu Layout