23
ANNUAL MAINTENANCE
EndURancE 50F
ANNUAL MAINTENANCE
To maintain safe operation and longevity of furnace this
maintenance needs to be followed.
Spring Shutdown
– after the last burn in the spring, cool
the furnace. Remove all fuel from the hopper and the auger.
Remove and clean all burn pot components, ash pan and ash
ports behind the ash pan.
1. The exhaust system should be thoroughly cleaned. call your
dealer for this service.
2. The mechanical area in the rear should be vacuumed.
3. apply grease to actuator slides.
4. The exhaust fan should be cleaned (may require a new gas-
ket). call dealer for this service. annual oiling of the motors
is not needed. (See Figure 15).
Fall Startup
–
1. Prior to lighting the first fire, check the outside area around
the exhaust and air intake systems for obstructions. Try all
controls to see that they are working prior to lighting a fire.
also check periodic maintenance items.
NOTE: Be sure to unplug the furnace before
accessing the rear of the furnace.
Remove side panel to allow access to the four bolts
holding the exhaust cover plate. To clean the fan
blades remove the exhaust cover plate, then slide the
restrictor plate up and to the left to remove.
Figure 15