Installation manual
CNC 8055
CNC 8055i
MA
CHINE PARA
METERS
6.
S
OFT
: V02.2
X
·281·
PLC Parameters
OANALOG1 (P111)
OANALOG2 (P114)
OANALOG3 (P117)
OANALOG4 (P120)
They are used to set the remote modules.
They indicate the number of analog outputs of each of the 4 remote modules; a CAN node number
identifies each one in the system. Its value will be 4 if it is a Fagor remote module.
PT100_1 (P112)
PT100_2 (P115)
PT100_3 (P118)
PT100_4 (P121)
They are used to set the remote modules.
They indicate the number of physical connections available for PT100 probes in each of the 4 remote
modules and also indicate which ones are connected. All this information is reflected in a 16-bit
string. Their value will be 0000 0000 00
00
00
11
if it is a Fagor remote module (2 physical
connections, bits 0 and 1 set to "1") and whether they are both connected (bits 4 and 5 set to "0")
or not. See table below.
A remote module may have physical connections for PT100 probes, but they are not connected.
That is why there is a bit indicating that there is a physical connection for the PT100 probe and
another bit to indicated whether a probe is connected or not.
Therefore, for a 16-bit string:
If the probe is not properly connected or the cable is defective, the CNC will display an error message
that will be treated like the errors at the digital inputs/outputs.
NUIANA1 (P122)
NUIANA2 (P124)
NUIANA3 (P126)
NUIANA4 (P128)
They are used to set the remote modules.
They indicate the number of the first analog input of each remote module. The rest of analog inputs
of the same module will be numbered sequentially.
NUOANA1 (P123)
NUOANA2 (P125)
NUOANA3 (P127)
NUOANA4 (P129)
They are used to set the remote modules.
They indicate the number of the first analog output of each remote module. The rest of analog outputs
of the same module will be numbered sequentially.
If the value of all these parameters is zero (they are by default), the numbering of the analog
inputs/outputs will be consecutive to the last local inputs/outputs.
Their maximum value will be 16, both for the analog inputs and analog outputs.
On power-up, the CNC verifies that the number of analog inputs/outputs detected at the module
matches the value assigned to the relevant machine parameters.
If these values do not match, the CNC screen will display a message indicating it and then it will
turn the remote module off.
PT100_1 = x x x x x x x x xx 0/1 0/1 xx 0/1 0/1
bit 0
Does it have a physical connection for PT100_1 probe? no / yes
0/1
bit 1
Does it have a physical connection for PT100_2 probe? no / yes
0/1
bit 4
Is there a PT100_1 probe connected to it? yes / no
0/1
bit 5
Is there a PT100_2 probe connected to it? yes / no
0/1
... others
Reserved
for Fagor remote modules
bit 15 .......
0
1
2
3
12 11 ....... 8 7 ........ 4
Summary of Contents for CNC 8055i
Page 1: ...CNC 8055 Installation manual Ref 1705 Soft V02 2x...
Page 8: ...8 Installation manual CNC 8055 CNC 8055i SOFT V02 2X...
Page 12: ...18 CNC 8055 CNC 8055i Declaration of conformity and Warranty conditions...
Page 16: ...10 CNC 8055 CNC 8055i Version history...
Page 22: ...16 CNC 8055 CNC 8055i Returning conditions...
Page 24: ...20 CNC 8055 CNC 8055i Additional notes...
Page 26: ...22 CNC 8055 CNC 8055i Fagor documentation...
Page 72: ...72 Installation manual CNC 8055 CNC 8055i 1 8055 CNC CONFIGURATION SOFT V02 2X Operator panel...
Page 227: ...Installation manual CNC 8055 CNC 8055i MACHINE PARAMETERS 6 SOFT V02 2X 227 Axis parameters...
Page 290: ...290 Installation manual CNC 8055 CNC 8055i 6 MACHINE PARAMETERS SOFT V02 2X Tables...
Page 474: ...474 Installation manual CNC 8055 CNC 8055i 10 PLC PROGRAMMING SOFT V02 2X PLC library...
Page 644: ......
Page 652: ...652 Installation manual CNC 8055 CNC 8055i B SOFT V02 2X Central unit of the 8055 CNC...
Page 654: ...654 Installation manual CNC 8055 CNC 8055i C SOFT V02 2X 11 LCD Monitor...
Page 656: ...656 Installation manual CNC 8055 CNC 8055i D SOFT V02 2X Probe connection at the 8055i...
Page 658: ...658 Installation manual CNC 8055 CNC 8055i E SOFT V02 2X Probe connection at the 8055 CNC...
Page 681: ...Installation manual CNC 8055 CNC 8055i J SOFT V02 2X 681 Key code MC operator panel...
Page 682: ...682 Installation manual CNC 8055 CNC 8055i J SOFT V02 2X Key code...
Page 683: ...Installation manual CNC 8055 CNC 8055i J SOFT V02 2X 683 Key code TC operator panel...
Page 684: ...684 Installation manual CNC 8055 CNC 8055i J SOFT V02 2X Key code...
Page 685: ...Installation manual CNC 8055 CNC 8055i J SOFT V02 2X 685 Key code MCO TCO operator panel...
Page 686: ...686 Installation manual CNC 8055 CNC 8055i J SOFT V02 2X Key code Alphanumeric keyboard...
Page 687: ...Installation manual CNC 8055 CNC 8055i J SOFT V02 2X 687 Key code 11 LCD Monitor...
Page 688: ...688 Installation manual CNC 8055 CNC 8055i J SOFT V02 2X Key code...
Page 692: ...692 Installation manual CNC 8055 CNC 8055i K SOFT V02 2X Logic outputs of key status...
Page 694: ...694 Installation manual CNC 8055 CNC 8055i K SOFT V02 2X Logic outputs of key status...
Page 698: ...698 Installation manual CNC 8055 CNC 8055i K SOFT V02 2X Logic outputs of key status...
Page 702: ...702 Installation manual CNC 8055 CNC 8055i L SOFT V02 2X Key inhibiting codes...
Page 704: ...704 Installation manual CNC 8055 CNC 8055i L SOFT V02 2X Key inhibiting codes...
Page 707: ...Installation manual CNC 8055 CNC 8055i L SOFT V02 2X 707 Key inhibiting codes 11 LCD Monitor...
Page 708: ...708 Installation manual CNC 8055 CNC 8055i L SOFT V02 2X Key inhibiting codes...
Page 722: ...722 Installation manual CNC 8055 CNC 8055i N SOFT V02 2X M functions setting chart...
Page 728: ...728 Installation manual CNC 8055 CNC 8055i Q SOFT V02 2X Maintenance...
Page 729: ...Installation manual CNC 8055 CNC 8055i Q SOFT V02 2X 729...
Page 730: ...730 Installation manual CNC 8055 CNC 8055i Q SOFT V02 2X...
Page 731: ......