ACCENSIONE PIEZOELETTRICA DEL GAS
(solo per modelli con + GAS)

Aprire il rubinetto dell'impianto del gas.
Ruotare, premendo, in senso antiorario la manopola rubinetto
gas (

4

) e premere ripetutamente il pulsante accensione

piezoelettrica (

3

) fino a che non si accende il bruciatore sotto

la caldaia.
Controllare l'avvenuta accensione dalla finestrella e dopo
alcuni secondi rilasciare la manopola (

4

).

PIEZOELECTRIC GAS IGNITION
(only for models with + GAS)

Open the gas tap.
Press and turn the gas tap knob (

4

) counter-clockwise and

repeatedly press the piezoelectric switch-on push-button (

3

)

until the burner under the boiler lights up.
Check through the observation window  that the burner is lit
and, after a few seconds, release the knob (

4

).

ALLUMAGE A PIEZO-ÉLECTRIQUE DU GAZ
(seulement pour modèles avec + GAS)

Ouvrir le robinet de l’installation du gaz.
Tourner dans le sens contraire, en appuyant,  la touche du
robinet du gaz (

4

) et pousser de façon répétée sur le bouton

d’allumage piézoélectrique (

3

) jusqu’à ce que le brûleur qui

se trouve sous la chaudière s’allume.
Vérifier l’allumage par la petite fenêtre et, après quelques
secondes, relâcher la touche (

4

).

PIEZOELEKTRISCH GAS EINSCHALTEN
(ausschl. für M GAS)

Den Gashahn aufdrehen.
Drücken Sie den Gasregler (

4

), und drehen Sie ihn gegen

den Uhrzeigersinn; drücken Sie mehrmals die Taste
‘piezolelektrische Zündung’ (

3

), bis daß der unter dem

Heizkessel installierte Gasbrenner gezündet wird.
Kontrollieren Sie die Zündung über das Schaufenster, und
lassen Sie den Gasregler (

4

) einige Sekunden nach erfolgter

Zündung los.

Installazione - Installation - Installation - Installation - Instalación - Instalação

ENCENDIDO PIEZOELECTRICO DEL GAS
(solo para modelos con + GAS)

Abrir el grifo de la instalación de gas.
Girar, apretando, en sentido contrario a las agujas del reloj
el mando de la válvula del gas (

4

) y pulsar repetidamente el

botón de encendido piezoeléctrico (

3

) hasta que no se

encienda el quemador que está debajo de la caldera.
Controlar que se hay producido el encendido desde la
ventanilla y después de unos segundos dejar de apretar el
mando (

4

).

ACENDIMENTO PIEZOELECTRICO DO GÁS
(apenas para modelos con + GÁS)

Abra a torneira da instalação do gás.
Rodar o manípulo torneira do gás (

4

) em sentido contrário

aos ponteiros do relógio, mantendo o mesmo carregado e
carregar várias vezes no botão de acendimento
piezoleléctrico (

3

) até o queimador, que se encontra debaixo

da caldeira, acender.
Verificar se a janela acendeu e após alguns segundos
abandonar o manípulo (

4

).

I

GB

F

E

D

P

4

3

Summary of Contents for Smart A2-grp

Page 1: ...n besten W nschen f r ein gutes Arbeiten mit lhrem neuen Ger t GRUPPOCIMBALIS p A Cher Client Nous vous f licitons pour l acquisition de votre nouvelle Faema Avec cet achat vous avez choisi une machin...

Page 2: ...n empleo impropio de la m quina para caf Lire attentivement les informations contenues dans ce manuel avant que vous n utilisiez et que vous ne manipuliez la machine caf de mani re erronn e En effet c...

Page 3: ...tserkl rung Uso Declaraci n de Conformidad CE Uso Declara o de Conformidade CE Smontaggio Disassembly Demontage Abmontierung Desmontaje Desmontagem Regolazioni Setting Reglages Einstellungen Regolacio...

Page 4: ...4 SMART A R 18 21 20 17 19 16 15 1 4 10 7 6 7 9 2 8 6 2 14 3 12 11 10 23 22...

Page 5: ...n continue 22 Levier Cappucinomatic 23 Cappuccinomatic Les d tails ne sont appliqu s qu certaines configurations de produits LEGENDE 1 Hauptschalter 2 Druckknopftafeln 3 Taste piezolelektrische Z ndun...

Page 6: ...t par le personnel technique qualifi et autoris ACHTUNG Die Installation die Demontage und die Einstellung des Ger tes darf nur durch entsprechend qualifizierte Fachkr fte vorgenommen werden ATENCI N...

Page 7: ...i sia prevista la pulizia mediante getti d acqua In ogni caso evitare di pulire l apparecchio con getti d acqua 13 Non ostruire le aperture o fessure di ventilazione o di smaltimento calore 14 In caso...

Page 8: ...de toute mani re la chaudi re ainsi que les conduites de circulation de l eau ANGABENZURINSTALLATION 1 Die im vorliegenden Anleitungsheft enthaltenen Anweisungen sind aufmerksam zu lesen da sie wichti...

Page 9: ...almacena en locales en los que la temperatura puede descender por debajo del punto de congelaci n vaciar en cualquier caso la caldera y los tubos de circulaci n del agua INDICA ESPARAAINSTALA O 1 Ler...

Page 10: ...er pressioni pi alte installare un riduttore di pressione for pressure beyond this value install a pressure reducer pour pression plus haute installer un det ndeur bei h heren Druckwerten Druckreduzie...

Page 11: ...co in un pozzetto dotato di sifone per l ispezione e la pulizia IMPORTANTE il tubo di scarico nelle curve NON deve avere un andamento come indicato in figura 2 in tal caso operare come indicato in fig...

Page 12: ...E Die Maschine mu vollkommen waagerecht stehen zu diesem Zweck sind die entsprechend verstellbaren F e zu verwenden dann sind die F e mit den Sperrmuttern zu sichern Die Wasseranschl sse sind nach Abb...

Page 13: ...ulicas seg n lo indicado en la figura 1 respectando las vigentes normas de siguridad hidr ulica del pa s de instalaci n Acordarse de interponer las relativas ensambladuras en los empalmes que unen los...

Page 14: ...de l installateur en cas de d g ts Contr ler galement le type de branchement indiqu sur l tiquette appos e sur le c ble d alimentation la tension doit correspondre celle qui est indiqu e sur la plaqu...

Page 15: ...de de los da os causados por una instalaci n lectrica defectuosa Recordamos adem s la responsabilidad del instalador en el caso de que se verificasen da os Adem s hay que controlar o tipo de liga o in...

Page 16: ...which an external potential equalizing wire should be connected This connection is ABSOLUTELY NECESSARY and must be made right after the machine is installed Use a wire whose cross sectional area con...

Page 17: ...regulations in mind the connection to gas tubig can be done with either a rigid tube or a flexible tube see Figure For installation with flexible tube Two hose adaptor connectors with differing dimens...

Page 18: ...n Anschlu an die Gasleitung sowohl ein Rohr als auch ein Schlauch verwendet werden siehe Abbildung Unter den mitgelieferten Extrateilen befinden sich 2 Schlauchhalterungsanschl sse zur leichteren Anbr...

Page 19: ...azadera que bloquea el quemador LIGA ODOG S apenas para modelos con GAS Respeitando as normas internacionais de seguran a a liga o do g s pode ser feita quer com tubo rigido quer com tubo flex vel ver...

Page 20: ...EKTRISCHGASEINSCHALTEN ausschl f r Modelle GAS Den Gashahn aufdrehen Dr cken Sie den Gasregler 4 und drehen Sie ihn gegen den Uhrzeigersinn dr cken Sie mehrmals die Taste piezolelektrische Z ndung 3 b...

Page 21: ...doit tre comme indiqu sur la figure 2 INSTALACIONDECALEFACCIONDEGAS solo para modelos con GAS Regulaci n de la combusti n La llama tiene que ser de color azul no tiene que alejarse del quemador y no...

Page 22: ...GKEIT berpr fen Sie ob die Bedingungen f r eine einwandfreieFunktionst chtigkeit gegeben sind 1 WASSERANSCHLUSS keine Austritte bei den Anschl ssen und Leitungen vorhanden 2 GASANSCHLUSS keine Austrit...

Page 23: ...cken Nebenbemerkung In dieser Gebrauchs und Wartungsanleitung wird erkl rt wie man das Wasser bzw das warme Wasser oder den Dampf ausstr men l t ATTENTION UNE FOIS TERMIN E L INSTALLATION ETAVANT DE...

Page 24: ...nd electronic equipment GRUPPO CIMBALI electrical equipment is marked with a pictogram of a garbage can inside a barred circle This symbol means that the equipment was sold on the market after August...

Page 25: ...o que representa un contenedor de basura sobre ruedas cruzado por una barra El s mbolo indica que el aparato fue introducido en el mercado despu s del 13 de agosto de 2005 y que debe ser objeto de rec...

Page 26: ...26...

Page 27: ...ccording to the EC Directives We GRUPPO CIMBALI S P A hereby declare that the design and construction of the machines designated below are conform to the relevant safety and health requirements of the...

Page 28: ...on the cup warming plate 11 Press the button 12 and check to see that the light turns on Don t switch on the gas installation when the boiler is under pressure Before using the machine check that the...

Page 29: ...ally Press the push button 21 for continuous dispensing Dispensing whether for dosed servings or in the continuous dispensing mode can be interrupted at any time by pressing the STOP push button 18 He...

Page 30: ...the desired temperature then lower the steam command lever 7 to stop the issue of steam Note At the conclusion of each steam dispensing phase clean the inside of the steam nozzle as follows turn the n...

Page 31: ...ny organic residue present Rinse carefully To clean the inside of the steam nozzle follow these steps Turn the nozzle towards the cup tray and carefully activate steam dispensing at least once Grille...

Page 32: ...fee machine being used for reasons other than its intended use Never work the coffee machine with wet hands or naked feet Cup warming plate Place only coffee cups cups and glasses to be used in conjun...

Page 33: ...does not dispense coffee SOLUTION Check the electricity supply Check the position of the ON OFF switch 1 Turn the ON OFF switch 1 to position 2 Clean using the special brush provided Use a finer grin...

Page 34: ...42 English English...

Page 35: ...r a parte lateral P E D F GB I Regolazioni Setting Reglages Einstellungen Regulaciones Regula es MACCHINAEQUIPAGGIATACON TERMOSTATO DI SICUREZZA Il termostato situato nella scatola elettrica In caso d...

Page 36: ...omba BOMBAVOLUMETRICACOM FILTRO Quando come a a fazer barulho limpiar o filtro F BY PASS A Porta de regula o press o bomba A F P E D F GB I PRESSOSTATO A Vite di regolazione pressione caldaia PRESSURE...

Page 37: ...Gr A S ON Dip 4 Dip 3 Dip 2 Dip 1 CN1A J1 J2 CN2 CN1 OFF ON CN10 CN11 OFF no bridge solenoid valve 24V CN10 CN11 ON bridge present solenoid valve 220V Mix mixer PRG programming CN10 CN11 OFF aucun pon...

Page 38: ...78 Schema elettrico Wiring diagram Schema electrique Elektrischer Schaltplan Esquema electrico Esquema el ctrico...

Page 39: ...8 10 11 17 19 20 21 22 26 27 28 29 30 31 32 33 34 36 38 39 41 LEGEND Interruptor general Indicador luminoso ON OFF Interruptor calienta tazas Dip switch Tarjeta electr nica Botones grupos Sonda nivel...

Page 40: ...80 Circuito idraulico Hydraulic circuit Circuit hydraulique Hydraulikplan Circuito hidraulico Circuito hidraulico...

Page 41: ...ppliqu s qu certaines configurations de produit LEGENDE 5 R ckschlagventil W rmetauscher 6 Strahler Dampfabgabe 8 Strahler Hei wasserabgabe 14 Druckmesser Heizkessel Pumpe 20 Sperrstift Magnetventil 4...

Page 42: ...82...

Page 43: ...ltigt kopiert oder ver ffentlicht werden Copyright by GRUPPO CIMBALI S p A Milano Alle Rechte vorbehalten GRUPPO CIMBALI S p A ViaA Manzoni 17 20082 Binasco MI Italy Tel 39 2 90 04 91 90 04 81 Fax 39...

Page 44: ...Bestellung bitte dem Vertreter die Katalog Nr angeben FAEMAe il SERVICE LINE Il servizio assistenza della societ FAEMA nell intento di essere vicino ai SIGG Clienti nella scelta dei prodotti per il m...

Reviews: