Anti-terrorism retractable oil-hydraulic bollard
!
!
!
!
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by quali ed and
authorized technicians in compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual, including at least
the minimum safety, command and signalling accessories as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Providing a suitable reinforcement metallic framework ensures that the breakout resistance value be respected as stated
in this manual.
NOTE
: the iron framework (all of the steel rebars) is not supplied by our company. It has to be made locally in
compliance with the technical data, drawings and all of the indications described in this installation manual. The
components of the structure developed in this way are able to make the most of the performance features of each
component and ensure the impact resistance features of the bollard as indicated.
5) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
6) Make sure the site is free from utilities that may interfere with the installation.
7) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop
detectors. The magnetic elds of other sources may affect the detection of the loops as well as those of other
command and safety devices of the system.
8) Make sure the power supply to the electric motor is 230 V (50 Hz).
9)
Recommended power supply cable: BUT FLESSIBILE FG 7OR 12x1,5 mm² up to 20 metres max.
Ground cable to have a section as required to comply with the site regulations.
10) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
11) The installer shall provide the nal user with information related to all of the operating commands and functions of the
system, including that concerning lowering of the post in case of an emergency (manual release operation).
12) The installer shall inform the nal user of the dangers coming from the presence of persons, especially children, in the
proximity of the bollard.
13) The manufacturer reserves the right to change this manual without previous notice.
As far as con guration and execution of the system are concerned, these are to comply with the laws in the country of
installation.
Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of materials
or accessories not approved by the company itself.
It is to be noted that the product respects the impact and breakout resistance values as indicated provided
that the installation of the same is carried out in observance of the speci cations included in this manual of
instructions. Various factors are to be carefully taken into consideration such as compaction index, soil
permeability coefficient, concrete type, which may affect the indicated values even signi cantly.
This symbol indicates that a particular attention is required on the installation phases and on running
the operator. Failure to observe these indications may cause incorrect functioning of the bollard.
PRODUCT SPECIFICATIONS
Fully retractable automatic bollard for heavy duty applications, certi ed and tested according to ASTM F2656-15 C750, PAS
68:2013 V/7500 (N3)/80 standards and IWA 14-1:2013 V/7200 [N3C]/80 standards; made up of two oil-hydraulic motor pump
units incorporated in the structure and one oil-hydraulic actuator inside the rising cylinder. Designed to stop a vehicle of 7,5
t at a speed of 80 km/h and remain perfectly intact and operative for the protection of sites under risk of attack and all those
areas where a high level of security and perimeter protection are required in case of a terrorist assault. IP 67. The height of the
rising cylinder (from ground) is 1.000 mm. Rising cylinder made of S355K2H steel, thickness 20 mm, cataphoresis treated and
powder coated. AISI 304 brushed stainless steel cover sleeve available for the rising cylinder. Rubber ring on rising cylinder
head with 12 signalling LEDs with ashing light. Cataphoresis treated aluminium cover, nished to provide a slip-proof
treading surface. Rising cylinder tted with high intensity, microprismatic, retrore ecting approved sticker (h 80 mm). Hot
dip galvanized steel casing for ground foundation. Impact resistance 700.000 J, breakout resistance 2.000.000 J. static load
max 2.800 kg in standing position, max 20.000 kg in lowered position. Working temperature -40 °C +80 °C. Supply voltage
230 Vac ± 10%, 50 Hz. Absorbed power 3.100 W. Connector and junction box IP 66 for cabling. Rising time ~ 5,0 s. Frequency
of use 2.000 cycles/day. Hydraulic device locking the bollard in standing position.