OPERATIONS FOR ORDINARY ROUTINE MAINTENANCE OF FADINI SEMIAUTOMATIC BOLLARDS (EVERY SIX MONTHS)
The standard maintenance routine sequence is as follows:
• Clean the ground cylinder and remove dirt by a vacuum cleaner.
• Clean water drains located at the bottom of the ground cylinder and/or excavation pit.
• Check the screws fastening the bollard to the ground cylinder, making sure they are properly tightened and lubricated.
• Check the correct functioning of the gas springs (if any are tted) and/or the levers system inside the bollard for unlocking and bollard removal
from its seat.
• Check the release system for bollard manual operations.
• Clean and recondition the rising cylinder if required, e.g.: paint patching up, replacing the retrore ecting approved sticker and /or the cover
tted with rubber edge.
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by quali ed and authorized technicians in
compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual.
3) Any application not indicated in this manual may cause malfunctioning or damage to people and properties.
4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
5) Make sure the site is free from utilities that may interfere with it.
6) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
7) The installer shall inform the nal user of the dangers coming from the presence of persons, especially children, in the proximity of the bollard.
8) The manufacturer reserves the right to change this manual without previous notice.
As far as con guration and execution of the system are concerned, these are to comply with the laws in the country of installation.
PRODUCT SPECIFICATIONS
Semiautomatic bollard, fully disappearing, consisting of pushing gas springs inside the moving cylinder, operated by a specially designed release
spanner. Suitable for applications in private, commercial areas, and urban installations. The height of the moving cylinder (from ground) is
500/600/700/800 mm. Moving cylinder made of S235JRH steel, thickness 4 mm and Ø 275 mm, cataphoresis treated and powder coated. AISI 304
brushed stainless steel cover sleeve available for the rising cylinder. Rubber ring on moving cylinder head. Moving cylinder tted with high
intensity, microprismatic, retrore ecting approved sticker (h 80 mm). Ground sleeve made of hot dip galvanized steel, walkable and carriageable
cover. Breakout resistance 320.000 J.
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under its own responsibility that
semiautomatic Talos
is in
compliance with the Machinery Directive 2006/42/CE, moreover: is to be sold and installed as a comprehensive “Automatic System”, including
the accessories and components as recommended by the Manufacturing Company. In observance of the current directives, any automation is to
be regarded as a “machine”. Therefore it is required that all the applicable safety norms are strictly complied with by the installation agents, who
are also required to issue a Declaration of Conformity. The manufacturing company is not liable for incorrect applications or misuse of its
products that are declared to be produced in compliance with the following norms: Analysis of the risk and actions to cure them EN 12445 & EN
12453, Low Voltage Directive 2014/35/UE, Electro-magnetic Compatibility Directive 2014/30/UE. In order to certify the product the Manufacturer
declares under his own responsibility the compliance with the PRODUCT regulations under the NORMS EN 13241-1.
Meccanica Fadini s.n.c.
Responsible Manager
Meccanica Fadini is not liable for any possible damage derived from incorrect use or from any use not indicated in this manual,
furthermore it is not answerable for malfunctioning caused by the use of materials or accessories not approved by the company
itself. It is to be noted that the product respects the breakout resistance values as indicated provided that the installation of the
same is carried out in observance of the speci cations included in this manual of instructions. Various factors are to be carefully
taken into consideration such as compaction index, soil permeability coefficient, concrete type, which may affect the indicated
values even signi cantly.
!
VERSION WITH LEDs FITTED ONTO THE COVER-RUBBER EDGE ASSEMBLY
As from week 28/2019 it will be available the TALOS in the version with Nos. 12 led lights tted onto the cover-rubber edge
assembly of the rising cylinder head.
This version replaces the correspondent model with Nos. 9 led lights in the top of the rising cylinder.
This technical improvement will not affect in any way the performance or the functional features of the bollard.
For a correct installation always refer to all the indications and gures shown in this installation manual.