8
Drwg. No.
4086
12
PLUS
GB
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control panel to the electric motor
General description:
the electronic control panel Elpro 12 Plus, new generation, is designed to operate the sliding gate operator Nyota 115. Power supply is
230V 50Hz single-phase. Built in full compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations
are recommended by a qualified technician in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel
any time.
Failure to follow installation regulations may result into serious damage to property and persons.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Make sure that the power supply to the electronic programmer is 230V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50m.
Use 1mm
2
section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate opening
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
PULIN 3
26
27
28
3
F4 Fuse = 1A
24V Transformer
Protection
RADIO
PLUG-IN
CARD
CONNECTOR
PEDESTRIAN OPENING
from 3 up to 30s
ELPRO 12 PLUS
18
16
17
CO
M
M
O
N
M
SINGLE-PHASE
ELECTRIC
MOTOR 230V
24V O
U
TPU
T (m
ax. load:
2 P
AIR
S PH
O
TO
CELLS
1 R
AD
IO
R
ECEIV
ER)
IN
D
ICA
TIO
N
LAM
P
24V m
ax. 3W
STO
P
CO
M
M
O
N
PU
SH
BU
TTO
N
S
O
PEN
CLO
S
E
P
H
O
TOCELLS
SA
FETY ED
G
ES
R
AD
IO
CO
N
TACT
LIM
IT SW
ITCH
CLO
SE
LIM
IT SW
ITCH
O
PEN
LIM
IT SW
ITCH
CO
M
M
O
N
COUR
TESY LIGHT
from 2 up to 255s
DWELL TIME
from 2 up to 128s
MOTOR RUN TIME
OPEN/CLOSE
from 2 up to 128s
F3 Fuse = 630mA
Transformer Protection
F2 Fuse = 8A
Mains
F1 Fuse = 8A
Mains
19 20
21 22
29
23
24
30
1
2
3
4
5
6
7
8
9
10
11 12 13 14 15
SAFETY C
ON
TACT
COU
R
TESY LIG
H
T
100W
m
ax.
CAP
ACITOR
230V 25W
m
ax.
FLAS
HIN
G LAM
P
230V
±
10%
SIN
GLE-PH
ASE
VO
LT
AG
E SU
PPL
Y
TRIMMER
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
L2
L3
L4
L5
L9
L8
L6
L7
L1
-
+
-
+
-
+
-
+
R65
R64
R63
R62
MICROPROCESSOR
E 12 plus 1 6
TRANSFORMER
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
PIC. 11
®