ELECTRICAL POWER CONNECTIONS
9
Drwg. No.
4086
GB
Flashing lamp:
19 20
230V MAX 25W
4
ON: Pre-flashing
OFF: No pre-flashing
7
ON: Lamp is not operating during
Dwell time. Automatic mode.
OFF: It flashes during Dwell Time.
Automatic Mode.
DIP-SWITCH 4 and 7:
1
2
Button switch:
3
4
5
6
STO
P
COM
M
ON
O
PEN
CLO
SE
12 13
1
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle is removed
OFF: Photocells do not stop gate while opening,
reverse it on closing in case of an obstacle
PHOTOCELLS
AND SAFETY EDGE
24V OUTPUT (500 mA) (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
Limit switch:
LIMIT SWITCH
CLOSE
CO
M
M
O
N
10
8
9
LIMIT SWITCH
OPEN
Light
ON
= Open gate
Light
OFF
= Closed gate
Flashing
(fast) 0.5s
= Closing gate
Flashing
(normally) 1s
= Opening gate
Flashing
(slowly) 2s
= gate is stopped
24V 3W Indication Light:
3
11
Push Button Switch Pulin 3:
26
27
28
3
COM
M
ON
Led to indicate status of
Open - Stop - Close
switches
Safety Contact:
Radio Contact:
CO
M
M
O
N
CO
N
TACT
R
AD
IO
7
3
- Open/Close (Standard)
- Travel reversing on
pulsing
- Step by step
2
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
5
ON: Step by step. Stop in between
OFF: Standard operating mode
DIP-SWITCH 2 and 5 (NEVER set BOTH of them ON
at the same time):
This contact must be
N.C. for the control
panel to be allowed to
work
14 15
Power supply:
POWER SUPPLY
230V
±
10% 50Hz
SINGLE-PHASE
21 22
Capacitor and Single-phase Motor (230V):
-
+
R65
MOTOR RUN TIME
OPEN/CLOSE
FROM 2 UP TO 128s
R64
-
+
DWELL TIME
FROM 2 UP TO 128s
29 30
18
16 17
C
O
M
M
O
N
M
Capacitor
20
μ
F for 0.5HP
40
μ
F for 1.0HP
Courtesy Light 230V max. 100W:
23 24
Trimmer R63
-
+
COURTESY LIGHT
FROM 2 UP TO 255s
12
PLUS
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
Photocells and Safety Edge:
LOW VOLTAGE ELECTRICAL CONNECTIONS
®