PIC. 8

1) FLASHING LAMP MIRI 4
2) PHOTOCELL RECEIVER POLO 44
3) REMOTE-CONTROLLED SWITCH

RECEIVER CRUASTRO

4) CONTROL PANEL ELPRO 10 PLUS CEI
5) 0.03 A DIFFERENTIAL MAGNETIC-THERMAL

CIRCUIT BREAKER

6) OPERATOR NYOTA 115
7) RACK

8)  REMOTE-CONTROLLED SWITCH TRANSMITTER 

CRUASTRO

9) SAFETY EDGE
10) KEYSWITCH PRIT 19
11) PLUG-IN RADIO RECEIVER ASTRO 43
12) AERIAL BIRIO A8
13) PHOTOCELL PROJECTOR POLO 44
14) PUSH BUTTON SWITCH PULIN 3
15) TRANSMITTER ASTRO 43/2 SMALL

- NYOTA 115 is fitted with an 

external safety microswitch

 

(1)

 which

disconnects the low voltage circuit whenever the operator cover
is removed; on request an extra 

internal safety microswitch

 

(2)

 can

be fitted to ELPRO 12 PLUS control box in order to disconnect the
230 V supply when the lid of the control box is removed. To ensure
the correct functioning of the system in case the a.m. parts are
removed, make sure that they are put back to the original position
to allow the respective contacts to be properly closed (pic.9).

LIMIT SWITCH STRIKING PLATES. FITTING INSTRUCTIONS

- Fix the 

limit switch striking plates

 as shown in the diagram: the distance between NYOTA 115 and the

 striking plate front surface line

must be 

15 - 20 mm

 approx. (pic. 5).

IMPORTANT: the gate must stop before hitting the gate post or special gate stops to prevent any damage to its structure.

ELECTRICAL CONNECTIONS

to the electronic control panel:

Voltage supply

electric motor, flashing lamp

 require 1.5 mm

2

 cables, which must not exceed a 50 m distance. For greater distances

the recommended cable square section is 2 mm

2

 (pic.8).

Limit switches, photocells, keyswitch, push button switch and accessories

: 1 mm

2

 cables can be used for these items (Pic.8).

- The safety 

pneumatic edge

 is to be fitted to the gate edge and is connected to the control box by a cable to be automatically rewound

to take up the slack. A 

remote

-

controlled switch

 can be fitted instead, 

series

 connected with the 

limit switch

 or the 

photocell receiver

.

- The electronic control panels type ELPRO 10 PLUS CEI and ELPRO 14 PLUS (for double bi-parting sliding gates only) are pre-set for all

required operations, automatic or semi-automatic, and are fitted with line relays and fault-detecting led indicators (pic.10 and 12).

IMPORTANT: Before connecting the system to the mains, position the 

voltage change-over switch

 to coincide with the site specifications

(either 230 V or 400 V); the switch is fitted onto the main boards of ELPRO 10 PLUS CEI and ELPRO 14 PLUS (Pic.10 and Pic.12). An option
is available where the control panel ELPRO 12 PLUS is incorporated in the operator (230 V single-phase only); for the electrical connections
follow the diagram pic. 11 (n.w. the limit switches and the electric motor are pre-wired).

- IMPORTANT: Fit the system with a 

junction box

 where all cables can be pre-terminated.

PIC. 9

INCORPORATED
CONTROL BOX
ELPRO 12 PLUS - 230 V

ROD TO OPERATE
THE 230 V MAINS
SWITCH

2

1

EXTERNAL VOLTAGE CUT OFF
MICROSWITCH

INTERNAL
VOLTAGE CUT OFF
MICROSWITCH

®

JUNCTION BOX WHERE
ALL CABLES ARE
PRE-TERMINATED

n

°

3x1,5

n

°

3x1

n

°

2x1

n

°

4x1,5

n

°

4x1

230 V

n

°

4x1

n

°

2x1

n

°

4x1

cable RG58

n

°

4x1

1

2

6

7

9

8

10

13

3

4

14

5

11

12

IMPORTANT: All the electrical equipment to be properly earthed

15

Summary of Contents for nyota 115

Page 1: ...NYOTA 115 Electro mechanical sliding gate operator GB Instruction manual ...

Page 2: ... not over travel the permitted limit and go out of the upper guide IMPORTANT Make sure that once at the end of the permitted travel the gate does not hit the gate posts or specially fitted gate stops to avoid damages to its structure FITTING NYOTA 115 ONTO THE FIXING BASE PLATE The first operation is to fix the fixing bracket to the ground and make sure that it is perfectly levelled Fixing distanc...

Page 3: ...ket Use a spare rack bar to make sure that junctions have the same rack pitch pic 7 Spot weld an angle bracket to the gate first then the rack in the same way if the welding type has been supplied or fix it to the gate by screws if either the nylon or galvanized type with fixing eyes has been supplied pic 6 IMPORTANT Before welding or fixing permanently any component make sure that the rack can me...

Page 4: ...r distances the recommended cable square section is 2 mm2 pic 8 Limit switches photocells keyswitch push button switch and accessories 1 mm2 cables can be used for these items Pic 8 The safety pneumatic edge is to be fitted to the gate edge and is connected to the control box by a cable to be automatically rewound to take up the slack A remote controlled switch can be fitted instead series connect...

Page 5: ...e installed in a sheltered dry place inside the box provided with it Make sure that the power supply to the electronic programmer is 230V 10 or 400V 10 Make sure that the power supply to the Electric Motor is 230V 10 or 400 V 10 For distances of over 50 metres we recommend using electric cables with bigger sections Fit the mains to the control panel with a 0 03A high performance circuit breaker Us...

Page 6: ...ication Light 3 11 26 27 28 3 COMMON Led to indicate status of Open Stop Close switches Radio Contact COMMON RADIO CONTACT 7 3 Open Close Standard Travel reversing on pulsing Step by step 2 ON Gate is not reversed while opening OFF Any pulse reverses the gate 5 ON Step by step Stop in between OFF Standard operating mode DIP SWITCH 2 and 5 NEVER set BOTH of them to ON at the same time Photocells an...

Page 7: ... holding is involved therefore a phisical attendance is required to keep the gate opening or closing until either the button or key is released DIP SWITCH 6 6 ON Deadman Control Dip switch 4 OFF and Dip switch 3 OFF OFF Standard Operations How it works Set the clock to the required time On the pre set time the gate is automatically opened and held open Any further pulsing even by remote control is...

Page 8: ...nd accessories Bridge terminals 1 and 2 if no photocells are required Bridge terminals 3 and 6 if no key or push button switches are required N W To fit extra accessories such as lights CCTV etc use only solid state relays to prevent damages to the microprocessor DIP SWITCH 1 4 5 6 7 8 2 ON OFF 3 Dip Switch 1 ON Photocells Stop while opening 2 ON Radio No reversing while opening 3 ON Automatic clo...

Page 9: ...2s gate is stopped 24V 3W Indication Light 3 11 Push Button Switch Pulin 3 26 27 28 3 COMMON Led to indicate status of Open Stop Close switches Safety Contact Radio Contact COMMON CONTACT RADIO 7 3 Open Close Standard Travel reversing on pulsing Step by step 2 ON Gate is not reversed while opening OFF Any pulse reverses the gate 5 ON Step by step Stop in between OFF Standard operating mode DIP SWI...

Page 10: ...any pulse opens the gate the gate stays open as long as the Dwell time expires as set by R64 trimmer then it closes automatically no pulsing is required Semi automatic Operation any pulse opens the gate that stays open A second pulse to Close is required for the gate to close Open and Close operations are achieved by holding a switch on no relay self holding is involved therefore a phisical attend...

Page 11: ...OFF 3 Dip Switch 1 ON Photocells stop gate on opening 2 ON Radio No gate reversing on opening 3 ON Automatic Closing 4 ON Pre flashing in service 5 ON Radio Step by step stop in between 6 ON Deadman Control Dip 4 OFF and Dip 3 OFF 7 ON Flashing lamp off on dwell time automatic mode 8 OFF blank Led Status Indication L1 Power supply 230V 400V 10 50Hz alight L2 Photocells If obstructed the led goes o...

Page 12: ... on Opening and reverse it on Closing once obstacle is removed OFF Photocells do not stop gate on Opening and reverse it on Closing if obstructed CONTACT FOR PHOTOCELLS AND SAFETY EDGE 24V OUTPUT MAX LOAD 2 PAIRS PHOTOCELLS 1 RADIO RECEIVER Limit switch LIMIT SWITCH CLOSING M1 COMMON 10 8 9 LIMIT SWITCH OPENING M1 Push Button unit Pulin3 Leds signalling the commands Open Stop Close Courtesy light ...

Page 13: ...0V 50Hz 10 Single phase or 400V 10 Three phase Both switches are to be set to the required voltage Automatic Semi automatic Pedestrian Opening With the gate in fully closed position it is possible to open the gate for pedestrians by pulsing to Open with Dip Switch No 6 ON terminals 3 4 a first Open pulse operates Motor 1 to open a second pulse operates the other gate to Open A pulse given to termi...

Page 14: ...A 115 incorporates an adjustable torque control system in an oil bath which can be adjusted to the gate weight A 13 mm spanner can be used for adjusting operations pic 15 1 Press and hold the retaining pin 2 By means of a 13 mm spanner unscrew the locknut the pin will lock the main shaft 3 Keep on holding the retaining pin pressed and tighten the adjustment screw power or unscrew it power 4 Tighte...

Page 15: ...r day 131 000 cycles Power supply Voltage output Low voltage output E M max power output Line fuses Secondary fuses Logic switching Box dimensions Protection standard Elesta relay marking ELPRO 10 PLUS CEI CONTROL PANEL Power transformer Magnetic core Voltage Output Frequency Insulation Main switch Contact rating 230 400 V 230 V 25 W 24 V 10 W 1 100 W 5 A 1A 630 mA Open Stop Close 280x200x110 IP 4...

Page 16: ...1000 STEEL GEAR RACK WITH FIXING SLOTS 30 x 12 mm THICKNESS M8x40 NYLON GEAR RACK 8 mm THICKNESS 1000 28x20 PIC 16 M8 GEAR RACK FIXING SET NYOTA 115 ELECTRO MECHANICAL TORQUE CONTROL IN OIL BATH BRONZE STEEL COUPLING STEEL GEAR RACK 22 x 22 mm THICKNESS FIXING BASE PLATE FOR CONCRETE EMBEDDING E 13 RELEASE SPANNER ...

Page 17: ...C LIMIT SWITCH WITH BRACKET The magnetic limit switch is fitted to the Nyota 115 and the permanent magnets are fitted to the gear rack moving along with the gate to the respective limit position on Opening and Closing cycles OPERATOR COVER CONTROL BOARD CONTAINER ELPRO 12 PLUS GEARED MOTOR NYOTA 115 IMPORTANT BEFORE FIXING THE SCREW MAKE SURE THAT THE ELECTRIC WIRES ARE FITTED THROUGH THE HOLE IN ...

Page 18: ... FIXING EYES MAGNET FIXING IS BY CLAMP LIVE LIVE COMMON 5mm Recommended distance LIVE LIVE COMMON 28x20 NYLON GEAR RACK MAGNET FIXING IS BY SCREWS 5mm Recommended distance LIVE LIVE COMMON 22x22 STEEL GEAR RACK MAGNET FIXING IS BY SCREWS GB Drwg No 1975 APPLICATION OF THE VERSION NYOTA 115 WITH MAGNETIC LIMIT SWITCH PIC 18 ...

Page 19: ...19 PIC 19 NYOTA 115 OVERALL DIMENSIONS 352 145 50 50 62 104 140 257 278 352 260 200 140 ...

Page 20: ...remarks in the book Safety Norms The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL...

Reviews: