4
PIC. 8
1) FLASHING LAMP MIRI 4
2) PHOTOCELL RECEIVER POLO 44
3) REMOTE-CONTROLLED SWITCH
RECEIVER CRUASTRO
4) CONTROL PANEL ELPRO 10 PLUS CEI
5) 0.03 A DIFFERENTIAL MAGNETIC-THERMAL
CIRCUIT BREAKER
6) OPERATOR NYOTA 115
7) RACK
8) REMOTE-CONTROLLED SWITCH TRANSMITTER
CRUASTRO
9) SAFETY EDGE
10) KEYSWITCH PRIT 19
11) PLUG-IN RADIO RECEIVER ASTRO 43
12) AERIAL BIRIO A8
13) PHOTOCELL PROJECTOR POLO 44
14) PUSH BUTTON SWITCH PULIN 3
15) TRANSMITTER ASTRO 43/2 SMALL
- NYOTA 115 is fitted with an
external safety microswitch
(1)
which
disconnects the low voltage circuit whenever the operator cover
is removed; on request an extra
internal safety microswitch
(2)
can
be fitted to ELPRO 12 PLUS control box in order to disconnect the
230 V supply when the lid of the control box is removed. To ensure
the correct functioning of the system in case the a.m. parts are
removed, make sure that they are put back to the original position
to allow the respective contacts to be properly closed (pic.9).
LIMIT SWITCH STRIKING PLATES. FITTING INSTRUCTIONS
- Fix the
limit switch striking plates
as shown in the diagram: the distance between NYOTA 115 and the
striking plate front surface line
must be
15 - 20 mm
approx. (pic. 5).
IMPORTANT: the gate must stop before hitting the gate post or special gate stops to prevent any damage to its structure.
ELECTRICAL CONNECTIONS
to the electronic control panel:
-
Voltage supply
,
electric motor, flashing lamp
require 1.5 mm
2
cables, which must not exceed a 50 m distance. For greater distances
the recommended cable square section is 2 mm
2
(pic.8).
-
Limit switches, photocells, keyswitch, push button switch and accessories
: 1 mm
2
cables can be used for these items (Pic.8).
- The safety
pneumatic edge
is to be fitted to the gate edge and is connected to the control box by a cable to be automatically rewound
to take up the slack. A
remote
-
controlled switch
can be fitted instead,
series
connected with the
limit switch
or the
photocell receiver
.
- The electronic control panels type ELPRO 10 PLUS CEI and ELPRO 14 PLUS (for double bi-parting sliding gates only) are pre-set for all
required operations, automatic or semi-automatic, and are fitted with line relays and fault-detecting led indicators (pic.10 and 12).
IMPORTANT: Before connecting the system to the mains, position the
voltage change-over switch
to coincide with the site specifications
(either 230 V or 400 V); the switch is fitted onto the main boards of ELPRO 10 PLUS CEI and ELPRO 14 PLUS (Pic.10 and Pic.12). An option
is available where the control panel ELPRO 12 PLUS is incorporated in the operator (230 V single-phase only); for the electrical connections
follow the diagram pic. 11 (n.w. the limit switches and the electric motor are pre-wired).
- IMPORTANT: Fit the system with a
junction box
where all cables can be pre-terminated.
PIC. 9
INCORPORATED
CONTROL BOX
ELPRO 12 PLUS - 230 V
ROD TO OPERATE
THE 230 V MAINS
SWITCH
2
1
EXTERNAL VOLTAGE CUT OFF
MICROSWITCH
INTERNAL
VOLTAGE CUT OFF
MICROSWITCH
®
JUNCTION BOX WHERE
ALL CABLES ARE
PRE-TERMINATED
n
°
3x1,5
n
°
3x1
n
°
2x1
n
°
4x1,5
n
°
4x1
230 V
n
°
4x1
n
°
2x1
n
°
4x1
cable RG58
n
°
4x1
1
2
6
7
9
8
10
13
3
4
14
5
11
12
IMPORTANT: All the electrical equipment to be properly earthed
15