5
Drwg. No.
4333
SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES
10
PLUS
CEI
GB
General description:
the electronic control panel Elpro 10 Plus CEI, new generation, is designed to operate sliding gates. Power supply is 230/400V single-
phase and three-phase. Built in full compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations
are recommended by a qualified technician in conformity to the existing safety standards.The manufacturing company declines any responsability for incorrect
handling and application; also, it reserves the right to change or update the control panel any time.
Failure to follow installation regulations may result in
serious damage to property and persons.
T
S
R
PULIN 3
26
27
28
3
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
L2
L3
L4
L5
L6
L7
L8
L9
1
7
4
10 11 12 13
19
20
2
8
5
3
9
6
STO
P
CO
M
M
O
N
OPEN
CLOSE
230V 25W max
FLASHING LAMP
230/400V
L1
L10
F4=630mA
Transformer
protection
F6=630mA
24V protection
RADIO
PLUG-IN
CARD CONNECTOR
TRANSFORMER
MOTOR RUN TIME
from 5 to 128s
DWELL TIME
from 5 to 128s
PEDESTRIAN
OPENING TIME
from 3 to 30s
-
+
-
+
-
+
-
+
EXT TIME (electric lock and
courtesy light) from 2 to 255s
T4
T3
T2
T1
PHO
TO
CELLS
SAFETY ED
G
E
RAD
IO
LIM
IT SW
ITCH
CLO
SE
LIM
IT SW
ITCH OPEN
CO
M
M
O
N
LIM
IT SW
ITCH
18
16
17
C
O
M
M
O
N
M
MOTOR
U
W
V
21
22
N
E
U
T
R
A
L
S
L
IV
E
23
22
ELECTRIC LO
CK O
R
12V AC R
ELA
Y FO
R
230V COU
R
TESY LIGHT
RS RS
CAPACITOR
230V 50Hz
SINGLE-PHASE
VOLTAGE SUPPLY
400V 50Hz
THREE-PHASE
VOLTAGE SUPPLY
N
E
U
T
R
A
L
L
IV
E
24V O
UTPUT m
ax. load:
2 pairs photocells
1 radio receiver
F1=8A mains
F2=8A mains
F3=8A mains
F5=1A flashing lamp
protection
Voltage cut off switch
and cover locking knob
ELPRO 10 PLUS CEI
IN
DICA
TIO
N LAM
P
24V m
ax. 3W
L
IV
E
L
IV
E
PIC. 10
!
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Make sure that the power supply to the electronic programmer is 230V
±
10% or 400V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10% or 400 V
±
10%
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.Use 1 mm
2
section wires for
limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is
230V
±
10% or 400V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
or 400 V
±
10%
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control panel to
the electric motor
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate opening
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
L10= It stays on for a time equal to the time set on T4
®