FUNCTIONS
21
18
16
17
19
22
23
20
ELECTRIC POWER CONNECTIONS
Trimmer T3
-
+
From 3 to 30 s activated by any
commanding pulse (even by remote
control), superior to 2s to
M1 Motor
5
ON: Step by step Stop in between
OFF: Standard operating mode
In this Mode, any pulse given by Radio remote control during the dwell time in Automatic mode option does
not allow any operation with the system . DIP-SWITCH No.2=ON, No.3=ON and No.5=ON
4
3
CO
M
M
ON
C
O
M
M
O
N
OPEN
NO
T3
Trimmer. Pedestrian
to zero value
Automatic cycle
: On pulsing to Open the gate is operated to open, stops for a time equal to the
dwell time as pre-set with T2 trimmer, after this time the gate is automatically operated to Close.
Semi-automatic Cycle
: On pulsing to Open the gate is operated to Open and held in open
position. A new pulse is needed for the gate to close.
Radio out of service on Dwell time in
Automatic Mode option:
3
ON= Automatic Closing
OFF= No Automatic Closing
Deadman Control:
DIP-SWITCH 6
6
ON= Deadman Control Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Normal operating mode
Time clock:
DIP-SWITCH No.3=ON Automatic Closing
3
ON= Automatic Closing
OFF= No automatic closing.
Semi-automatic
option
-
+
2
ON: No gate travel reversing on Opening
OFF: Any new pulse reverses gate travel
4
ON: Pre-flashing
OFF: No pre-flashing
7
ON: No flashing with the lamp on
Dwell time. Automatic mode
OFF: Flashing on Dwell time in Automatic mode option
DIP-SWITCH 4 and 7:
230V
400V
230V 50Hz
±
10%
SINGLE-PHASE
21
22
N
E
U
T
R
A
L
S
L
IV
E
23
22
230/400V
Single- and three-phase motors:
Control board power supply:
Flashing light:
FADINI
l'apricancello
19 20
FLASHING LIGHT
230V - 25W max
F i t t h e m a i n s t o t h e c o n t r o l b o a r d w i t h a 0 . 0 3 A h i g h
sensitivity, magnetic-thermal, differential circuit breaker
The board can be supplied 230V 50Hz
±
10% Single-phase or
400V
±
10% Three-phase. Both switches are to be set to the
required voltage.
Automatic / Semi-automatic:
Pedestrian Opening:
With the gate in fully closed position, it is possible to open the gate for pedestrians by
pulsing to Open with
Dip-Switch No.6=ON
terminals 3-4
:
- a first Open pulse operates
Motor 1
to open
- a second pulse operates the other gate to Open
A pulse given to terminals 7 - 8 (Radio Contact) by the remote control always operates both gates.
230 VOLT
400 VOLT
Pre-flashing (Dip-Switch 4=ON)
: Once an Open
pulse is given, after 3 seconds M1 motor starts
Once the gate is fully closed, the lamp goes on
flashing for 3 more seconds.
21
22
T
R
S
L
IV
E
23
22
400V 50Hz
±
10%
THREE-PHASE
DWELL TIME
from 5 to 128s
-
+
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No automatic closing
Semi-automatic mode
Trimmer T2
MOTOR RUN TIME OPEN /
CLOSE FROM 5 TO 128s
-
+
T1
Trimmer T1
T2
-
+
Trimmer T2
DWELL TIME
from 5 to 128s
CAPACITOR
18
16
17
C
O
M
M
O
N
M1
MOTOR
U
W
V
C
O
M
M
O
N
32
30
31
M2
MOTOR
U
W
V
CAPACITOR
Motor for
pedestrian
opening
Trimmer T3
Important:
Depending on the site voltage requirements
i t i s a b s o l u t e l y n e c e s s a r y t o s e t b o t h
switches accordingly
230V
400V
230/400V
How it works: Set the clock to the required time. On the set time the gate is operated to open and held
open. No other operations can be achieved (not even by remote control) until the time set on the clock
has expired. On expiring of the clock time and after the dwell time of the system, the gate is automatically
operated to close.
Trimmer T3 is to be set on to zero, Dip-Switch No. 3=ON
Open and Close operations are by "hold on switched" control (no
relay self-holding is involved). The automation is to be attended
and the command unit is required to be held switched to achieve
gate operation. Any operation is stopped on releasing the button
or key.
13
Drwg. No.
4198
GB
14
PLUS
230V-400V SINGLE- /THREE-PHASE CONTROL BOARD
DESIGNED FOR AUTOMATIONS TO OPERATE BI-PARTING SLIDING GATES
®