OPERATING MODES
7
Drwg. No.
4333
SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES
10
PLUS
CEI
GB
Remote Controlled Operations Excluded during Dwell Time on Automatic Mode:
3
5
With this setting it is not possible to operate the gate by remote control during the
dwell time on automatic mode. DIP-SWITCH 2=ON, 3=ON and 5=ON
2
Hold on switched (Deadman) control:
Pedestrian Opening:
Trimmer T3
-
+
from 3 to 30s. It can be activated by any pulse
(eg. by remote control), superior to 2s
Automatic / Semiautomatic:
Automatic Operation
: any pulse opens the gate, the gate stays open as long as the Dwell time expires
as set by T2 trimmer, then it closes automatically, no pulsing is required.
Semi-automatic Operation
: any pulse opens the gate that stays open. A second pulse to Close is required
for the gate to close.
Open and Close operations are achieved “by holding a switch
on” (no relay self-holding is involved) therefore a phisical
attendance is required to keep the gate opening or closing
until either the button or key is released.
DIP-SWITCH 6
6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
How it works: Set the clock to the required time. On the pre-set time the gate
is automatically opened and held open. Any further pulsing (even by remote
control) is not accepted by the system until the time pre-set by the clock has
expired. On expiring and after the pre-set dwell time the gate is closed
automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH N
°
3=ON Automatic Closing
3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
-
+
Pedestrian Trimmer T3
set on to zero
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
Dwell Time
from 5 to 128s
-
+
T2
CO
M
M
O
N
O
PEN
4
3
Time clock installation:
4
3
CO
M
M
O
N
CO
M
M
ON
O
PEN
NO
External Time Clock
ON= Automatic Closing
OFF= Closing by Pulse
ON: Step by step. Stop in between
OFF: Standard Operations
ON: No reversing on opening
OFF: Travel reversing on any pulsing
®