background image

TECHNICAL DATA
OIL-HYDRAULIC OPERATOR

Opening time 
 

stroke 150 mm 

(P5): 10 s + Br.T.

 

stroke 280 mm 

(P3): 26 s + Br.T. 

(P5): 17 s + Br. T.

 

stroke 400 mm 

(P3): 37 s + Br.T. 

(P5): 26 s + Br.T. 

Piston 

diameter 

  45 

mm

Shaft 

diameter 

  20 

mm

Thrust power 

 

 

(P3): 0 ÷ 6.300 N    (P5): 0 ÷ 5.400 N

Average working pressure 

 

1 MPa (10 bar)

Maximum pressure  

 

3,5 MPa (35 atm)

Hydraulic oil 

 

 

Fadini Oil - code 708L

Working temperature 

 

- 25 °C + 80 °C

Protection 

grade 

  IP 

67

Weight complete with accessories 

9,5 kg (stroke 150 mm)

    11 

kg 

(stroke 

280 

mm)

    14 

kg 

(stroke 

400 

mm)

Br. T. = Braking Time, varies depending on the setting done on the operator

Note: beyond 2,0 meters of gate width, it is always recommended that a gate 
lock be fitted

.

ELECTRIC MOTOR

Power output 

 

0,18 kW (0,25 HP)

Absorbed power   

250 W

Supply voltage 

 

230 Vac - 50 Hz

Absorbed current   

1,2 A

Motor rotation speed 

1.350 rpm

Capacitor 

  12,5 

μF

Intermittent service 

S3

PERFORMANCE

Frequency of use   

very intensive

Duty cycle (P5) 

 

opening 17 s

   dwell 

30 

s

   closing 

21 

s

   dwell 

40 

s

Time of one complete cycle  108 s
Complete cycles 

 

n° 33/hour

Annual cycles
(8 hours per day)   

n° 81.760 cycles

universal oil-hydraulic operator for swing gates 

HINDI 880 - evo

English

24

Via Mantova, 177/A - 37053 Cerea (VR) Italy 
Ph. +39 0442 330422 

Fax +39 0442 331054

[email protected] - www.fadini.net

GB

2012/19/UE

 Directive

Re. disposal of electric

and electronic waste

DISPOSE PROPERLY OF MATERIALS

ARMFUL TO THE ENVIRONMENT

94

117

94

82

117 mm

92

80

L

15*

C

L0

L1

100

1

1,5

2

3

4

8

2,8

200

300

400

500

600

Stroke 150 mm

Stroke 280 mm

Stroke 400 mm

Stroke 400 mm*

*Special version

MAX GATE WIDTH PER LEAF (m)

MA

X GATE WEIGHT PER LEAF (k

g)

The gate structure, design (solid, in-filled), height and strong wind 
pressure may affect and decrease the indicated values. Make always 
sure the gate structure is adequate to automation.

C

 (actual stroke)    

L           L0* 

L1*

                  [mm]

145 

 

   830 

605 

   750

275  

1.094 

732 1.007

395  

1.374 

885 1.280

* these distances can vary depending

on the position of the ball bearing eye 

2018/07

istr_hindi880evo_GB.ai   12   18/06/2018   11:25:25

Summary of Contents for Hindi 880-Evo

Page 1: ...EN 13241 EN 12453 EN 12445 universal oil hydraulic operator for swing gates GB Instructions manual pages 13 24 13 the gate opener ...

Page 2: ...allation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and components of the installation risk analysis verification of safety accessories verification of impact forces and reporting of residual risks INFORMATION FOR END USERS The end user is required to read carefully and to receive information concerni...

Page 3: ...rd is required for the functioning of the operator and has to be externally installed in a sheltered place The electronic unit controls all the moving functions either in automatic or semi automatic modes depending on the user s requirements The operator can come complete with a range of accessories that ensure safety and full control of the operations in any application public or private COMPONEN...

Page 4: ...ss key switch code 371L 13 VIX 53 4 TR code 5313GL 230 V 50 Hz 10 4x1 mm 4x1 5 mm 2x1 mm 4x1 mm 2x1 mm 2x1 mm RG58 1 2x1 mm 2 3 4 5 6 6 7 8 5 9 9 4 10 4x1 5 mm 13 11 11 10 12 Pic 3 Pic 4 The electric cable must dangle free of any impediment during the opening and closing movements of the gates 4x1 5 mm FIRST OPERATIONS TO RUN THE PISTON SHAFT Before fixing the operator to the gate and gate post po...

Page 5: ...hing plates not supplied by the manufacturer Reinforcement patching plate optional With heavy installations it is recommended to provide a plate adequate to the gate type PREPARING THE FIXING PLATES First weld the front and rear fixing plates to the patching plates Pic 5 after assessing the installation measurements as indicated in Pic 6 and Pic 7 or in Pic 8 in the case where opening is required ...

Page 6: ...he locknut hard by means of a 19 wrench Holding spanner included it allows for the piston shaft to be hold steady while the locknut is being tightened Operator rear fixing Operator front fixing It is always recommended before the operator fixing is finally completed that a few manual tests be carried out with Hindi 880 evo to assess that the installation distances are correct Pic 7 FIXING GEOMETRY...

Page 7: ...NOTE WELL the oil hydraulic operator Hindi 880 evo comes FACTORY PRE SET as a bidirectional locking and non braking unit HYDRAULIC LOCKING IN CLOSED POSITION version In case of power failure the gate can only be closed by hand Tighten through the end ONLY the CLOSING by pass avoid overtightening and unscrew the OPENING by pass by 2 turns maximum To unlock and manually operate the gate use the rele...

Page 8: ... slightly undo this screw to adjust the braking speed during the last stretch of the piston stroke Non BRAKING ON OPENING version Loosen the adjusting screw by 1 2 turns max Braking on opening adjusting screw Braking on closing adjusting screw Pic 15 Pic 16 Pic 17 Pic 18 Loosen Loosen Coded key to open the cover lid To unlock turn anti clockwise by 1 2 turns Braking Braking Inner manual release ke...

Page 9: ...o be fitted to the gate leaf closing first Electric lock catching plate to be fixed to the ground Gate stop plate in closed position Horizontal electric lock Vertical electric lock Screwdriver to adjust power Pic 19 Pic 20 Pic 21 ADJUSTING THE THRUST POWER In order to adjust the thrust power in opening and closing loosen or tighten the screws located inside the valve block cover to be accessed by ...

Page 10: ... slit Rear cap Slit allowing the gland and power supply cable to pass through it Cover front plug Hexagonal grommet nuts use the supplied spanner to remove them Operator cover Pic 22 Pic 23 FITTING THE REAR PROTECTION CAP AND COVER FIXING NOTE WELL The power supply electric cable is ALWAYS to be positioned on the side opposite the rear fixing plate between the bolt and the operator end casting uni...

Page 11: ...or model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors off...

Page 12: ...requency of use very intensive Duty cycle P5 opening 17 s dwell 30 s closing 21 s dwell 40 s Time of one complete cycle 108 s Complete cycles n 33 hour Annual cycles 8 hours per day n 81 760 cycles universal oil hydraulic operator for swing gates HINDI 880 evo English 24 Via Mantova 177 A 37053 Cerea VR Italy Ph 39 0442 330422 Fax 39 0442 331054 info fadini net www fadini net GB 2012 19 UE Directi...

Reviews: