ON
: motor run time max 90 s
OFF
: motor run time max 18 s
DIP-SWITCH N° 12:
12
-
+
T1
MOTOR RUN
TIME
1 s - 22 s
-
+
T2
DWELL
TIME
1 s - 180 s
12
Elpro S40
The acoustic signal device inside
the bollard is active duringrising
and lowering. The connection wires
are the
blue-common
and the
black
one of the flashing light
cable.
Acoustic signal device
230 V - 100 W max
BLUE
COMMON
BLACK
52
51
53
PCB power supply:
PCB power supply 230 V ±10% 50 Hz single phase
LIVE
F
N
NEUTRAL
Electronic programmer power
supply.
23
22
24
25
Signal led lights:
Output for intermittent signal led
lights during the movement both
rising and lowering and also on
dwell in up position: the lights are
off only when the bollard is in down
position.
Connect the
blue-common
wire
and the
brown
wire of the bollard
flashing light cable.
Signal led lights output
230 V - 100 W max
BLUE
COMMON
BROWN
52
51
53
It is possible to connect both the
external flashing lamp and the
intermittent signal led lights which
are on only during the rising and
lowering movement. The cable for
the connection is the one labelled
as flashing lights cable.
ON
: pre-flashing
OFF
: no pre-flashing
DIP-SWITCH N° 4 and N° 10:
4
ON
: flashing light out of service on dwell time.
Automatic mode
OFF
: light flashes on dwell time. Automatic mode
10
GB
ELECTRONIC CONTROLLER UP TO 4 AUTOMATIC BOLLARDS,
WITH OR WITHOUT LIMIT SWITCH
ELECTRICAL POWER CONNECTIONS
Accessory
Electrical connections
Dip-switch setting and LED indication of functions
Acoustic signal “beeper”
during movement:
External flashing lamp:
230 V - 100 W max
COMMON
52
51
53
Motors:
Important:
when doing the electric power connections it is
better to connect only one motor and its respective limit
switches. Put the posts into phase one by one.
20 μF additional capacitor
in case of power shortage
for Motor M1
16 17 18
A
B
M1
COMMON
MOTOR M1
Post n° 1
20 μF additional capacitor
in case of power shortage
for Motor M2
19 20 21
A
B
M2
COMMON
MOTOR M2
Post n° 2
20 μF additional capacitor
in case of power shortage
for Motor M3
31 32 33
A
B
M3
COMMON
MOTOR M3
Post n° 3
20 μF additional capacitor
in case of power shortage
for Motor M4
MOTOR M4
Post n° 4
34 35 36
A
B
M4
COMMON
istr_elpro-s40_GB.ai 5 07/07/2023 16:05:44