10
Elpro S40
LOW VOLTAGE ELECTRICAL CONNECTIONS
DIAGNOSTIC LEDS
ON
: it does not reverse on opening
OFF
: it reverses at any pulse
DIP-SWITCH N° 2 and N° 5:
2
ON
: step by step with stop in between
OFF
: standard operation
5
ON
: photocells or loop stop while opening,
reverse on closing once obstacle is removed
OFF
: photocells or loop do not stop while opening,
reverse on closing in caseof an obstacle
DIP-SWITCH N° 1 and N° 11:
1
ON
: during dwell time, automatic mode
(dip-switch 3 = ON) after engaging the
photocellsor loop, it closes 5 s later
OFF
: it does not close after engaging
the photocells or loop
11
Photocells
or loop detectors:
Key-switch:
Radio contact
(step by step mode):
Indication lamp output
24 V max 3 W:
Electric valve power supply:
24 Vdc output:
Accessory
Dip-switch setting and LED indication of functions
NO and NC contacts to be connected
to the respective terminals in the
key-or button-switches. All of the
possible setting combinations are
described in the instructions sheets
included with the respective control
accessories
- Opening only:
dip 2 = ON
and
dip 5 = OFF
- Gate travel reversing by any pulse
dip 2 = OFF
and
dip 5 = OFF
- Step by step: open-stop-close-stop
dip 2 = OFF
and
dip 5 = ON
- No new pulse is accepted in opening.
In dwell phase and in closing any new
pulses tops and reverses gate travel:
dip 2 = ON
and
dip 5 = ON
Output for a 24 V max 3 W indication lamp showing the status of the system:
Lamp
ON
= post in down position, free passage
Lamp
OFF
= post in up position, closed passage
Flashing
0,5 s (fast)
= rising post
Flashing
1 s (normally)
= lowering post
With external clock:
2 short flashes
followed by a longer pause
Output for 24 Vdc applications
24 Vac output
max load:
2 pairs photocells
1 radio receiver
Photocells or
Loop detectors
L3 OFF
= no OPENING contact,
it goes on whenever an opening pulse is given
L4 OFF
= no CLOSING contact,
it goes on whenever a closing pulse is given
L5 ON
= STOP contact closed,
it goes off whenever a stop pulse is given
3
3
7
4 5 6
NC
NO
NO
COMMON
COMMON
3
8
COMMON
RADIO
CONTACT
OPEN
CLOSE
STOP
L6 OFF
= no RADIO contact,
it goes on by any radio pulse
Electrical connections
L1
= pedestrian opening, normally
OFF
, alight when a pedestrian open pulse is given
L2
= photocells or loop, normally
ALIGHT
, if obstructed light goes off
L3
= open, normally
OFF
, alight when an open pulse is given
L4
= close, normally
OFF
, alight when a close pulse is given
L5
= stop, normally
ON
, it goes off when a stop pulse is given
L6
= radio, normally
OFF
, alight when a radio pulse is given
L7
= normally
ON
, mains voltage and fuse integrity F1, F2, F3, F4
L8
= limit switch open M1, normally
ON
, it goes off when the post is in down position
L9
= limit switch close M1, normally
ON
, it goes off when the post is in up position
L10
= limit switch open M2, normally
ON
, it goes off when the post is in down position
L11
= limit switch close M2, normally
ON
, it goes off when the post is in up position
L12
= limit switch open M3, normally
ON
, it goes off when the post is in down position
L13
= limit switch close M3, normally
ON
, it goes off when the post is in up position
L14
= limit switch open M4, normally
ON
, it goes off when the post is in down position
L15
= limit switch close M4, normally
ON
, it goes off when the post is in up position
DIP-SWITCHES
1 = ON
Photocells or loop stop while opening
2 = ON
Radio no reversing while opening
3 = ON
Automatic closing
4 = ON
Pre flashing activated
5 = ON
Radio step by step stop in between
6 = ON
Pedestrian opening motor M1 only one post operating
7 = ON
Deadman control
8 =
Traffic lights (see functions)
9 =
Traffic lights (see functions)
10 = ON
No lamp on during dwell time
11 = ON
Close on dwell time after passage through photocells or over the loop
12 = ON
Max working time 90 s. OFF = 18 s
1 2 3 4 5 6 7 8 9 10 11 12
ON
OFF
9 10
1 2
L2 ON
= no obstacle,
it goes off in case of obstuction
+
-
55 56
ELECTRICAL POWER CONNECTIONS
Accessory
Electrical connections
Dip-switch setting and LED indication of functions
23
22
24
25
230 V power supply
for 24 Vdc solenoid valve stabilizer
GB
ELECTRONIC CONTROLLER UP TO 4 AUTOMATIC BOLLARDS,
WITH OR WITHOUT LIMIT SWITCH
istr_elpro-s40_GB.ai 3 07/07/2023 16:05:44