FOR
SWINGING GA
TE
SYSTEMS
Dip-B N°1=OFF
27
Dip-Switch A
1 = ON
Photocells stop gate in opening
2 = ON
Radio, no reversing in opening
3 = ON
Automatic closing
4 = ON
Pre-flashing in service
5 = ON
Radio step-by-step
6 = ON
Traffic lights mode
limit switches connected
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - A
meccanica
FADINI
FOR
SWINGING GATE
AUTOMATIC SYSTEMS
:
set Dip Switch B N°1= OFF
2 3 4
1
ON
OFF
DIP-SWITCH - B
7 = ON
Stroke reversing pulse in Opening cycle
8 = ON
No gate delay in Opening, motors start together
9 =
2
nd
pair photocells in service
10 = ON
Flasher off in Dwell time
11 = ON
Gate re-closing in Opening and Dwell on engaging the photocells
12 = ON
Memory of motor run time settings enabled
, with installations
where very frequent operations are required
Dip-Switch B
1 = OFF
SWINGING GATE
mode
2 = ON
Hold-on-switched (deadman ) control
3 = ON
Traffic lights "yellow" for 3 seconds
4 = ON
DSA control by photocell transmitters if connected to the dedicated terminals
1 2 3 4
ON
OFF
DIP-SWITCH - B
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
Key-switch:
NO and NC contacts to be connected
to the respective terminals in the key-
or button-switches.
All of the possible setting combinations
are described in the instructions sheets
included with the respective control
accessories
3 4 5 6
FA
D IN
I
FA
D IN
I
NC
OPEN
CLOSE
ST
OP
COMMON
L4 OFF
= no OPENING contact, it goes on
whenever an opening pulse is given
L5 OFF
= no CLOSING contact, it goes on
whenever a closing pulse is given
L6 ON
= STOP contact closed, it goes
off whenever a stop pulse is given
1
st
pair photocells:
fitted outside
perimeter
1
DIP-SWITCH-A N° 1:
NC
NC
1 2
2
nd
pair photocells:
fitted inside perimeter
1 2
DIP-SWITCH-A N°9:
9
ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - Dip Switch B n°1=OFF
12 13
12 13
24Vac output
max. load:
n°1 radio receiver
n°3 pairs photocells
All NC contacts of safety
accessories such as
Photocells (receivers)
must be connected in
series with terminals
1 and 2
NC
FADINI
FADINI
Accessory
Electrical connections
Dip-Switch setting and LED indication of functions
ON
: Photocells 2
nd
pair in service
OFF
: Photocells 2
nd
pair not installed
L0 ON
= no obstacle detected, it goes off
in case of obstacle
24Vac output
max. load:
n°1 radio receiver
n°3 pairs photocells
Dip A No.9=ON and the NC contact connected:
The gates
stay stopped as long as the photocells are obstructed.
- In opening cycle: obstacle removed, gates go on opening
- In closing cycle: obstacle removed, gate travel reversed
NOTE: if no 2
nd
pair photocells are used, it is not necessary
to bridge the contact input, only DIP-SWITCH-A No. 9=OFF
ON
: stop gate/s in opening and reverse travel in
closing when cleared
OFF
: no stop in opening and reverse travel in
closing when obstructed
L1 ON
= no obstacle, it goes off
in case of obstraction
DIP-SWITCH-A N°2 and N°5 :
RADIO
CONTACT
COMMON
3
7
L7 OFF
= no RADIO contact, it goes on by
any radio pulse
FA
D IN
I
Radio contact
(step by step mode):
Any NO connection to these two terminals
will perform the following:
- Opening only:
Dip 2=ON and Dip 5=OFF
- Gate travel reversing by any pulse
Dip 2=OFF and Dip 5=OFF
- Step by step: Open-Stop-Close-Stop
Dip 2=OFF and Dip 5=ON
- No new pulse is accepted in opening.
In Dwell phase and in closing any new
pulse stops and reverses gate travel:
Dip 2=ON and Dip 5=ON
ON
: It does not stop and reverse gate travel
in opening
OFF
: always stops & reverses in opening
2
ON
: step by step with intermediate stop
OFF
: gate travel reversed by any radio pulse
5
1
2
3
4
5
6
7
8
9
A
B
ST
OP
Indication lamp
output
24V- max 3W:
COMMON
3
11
Output for a 24V max 3W indication lamp
showing the status of the system:
Lamp
On
= Gate open
Lamp
Off
= Gate closed
0.5s (fast)
flashing = gate closing
1s (normal)
flashing = gate opening
GB