Dip-B N°1=OFF

27

UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz

27

3

DIP-SWITCH-A N°3:

RE-CLOSING BY PASSING ACROSS THE PHOTOCELLS: in opening and dwell cycles
(DIP-A N°3=ON)

Gate is automatically closed after 3s from passing between the photocells.
In case a second pair of photocells are installed, (Dip 9=ON), both pairs are to be
passed across.

24V ac Output

for photocell

transmitter TX

enabled for 

DSA control

16

15

FUNCTIONS FOR SWINGING GATE OPENING - Dip Switch B n°1=OFF

-

+

AUTOMATIC / SEMI-AUTOMATIC:

Automatic Cycle:

 by one pulse from the open command the gate opens and stops in

Dwell mode for the time as pre-set on the 

Dwell Trimmer

. When this time expires the gate

closes automatically.

Semi-automatic Cycle: 

by one pulse from the open command the gate opens and stops

in fully open position. To close the gate, a close pulse is needed.

DSA: PHOTOCELL AUTOMATIC CONTROL:

For the 

DSA

 control (

D

evice for 

S

afety 

A

uto-test) it is necessary to

connect 

only the photocell transmitters (TX) 

to this output and

select 

Dip-B No.4=ON:

 if this function is enabled, ELPRO 27 checks

that all the connected photocell devices are cleared from obstacles
and properly working before starting any door/gate movements, otherwise
the door/gate is not started.

PEDESTRIAN OPENING:

With the gate in fully closed position, a pulse to terminals
3-8 operates the gate for pedestrians.

(On pedestrian mode, it is advisable to set Dip-A N°3= ON
for automatic re-closing).

The function "

Pedestrian Opening

" is not in service during

the first operation cycle, after a power failure.

L8 OFF 

= no pedestrian contact given,

                it goes on by pulsing for pedestrians

3 4 5 6 7 8

OPEN

PEDESTRIANS

Dip - Switch setting and LED indication of functions

Description

Dwell Trimmer:

 adjust dwell time

on automatic mode
from 1s up to 220s

ON

: Automatic closing

OFF

: Semi-automatic, closing by pulse

DIP-SWITCH-A N°9 and N°11:

11

ON

: Automatic closing on passing across

       the photocells after 3 seconds

ON

: 2

nd

 pair photocells enabled

OFF

: 2

nd

 pair photocells not installed

9

OFF

: No automatic closing on passing across

         the photocells after 3 seconds

4

ON

: DSA safety control enabled

OFF

: DSA safety control disabled

DIP-SWITCH-B N°4:

DEADMAN (HOLD-ON-SWITCHED) CONTROL:

The open/close operations are achieved by " holding on a command
switched" (the relays are not self-holding) and consequently the user must
be actively present during  gate movements until the push-button or the
key-switch is released.

2

ON

: Deadman control enabled

OFF

: Deadman control disabled

DIP-SWITCH-B N°2:

3

ON

: Automatic closing

DIP-SWITCH-A N°3:

COMMON

N.O.

External clock

3 4

OPEN

COMMON

STROKE REVERSING PULSE IN OPENING CYCLE

This function helps the gate electric lock to release with the gate/s in fully closed
position,even in "Pedestrians" mode: the gates in closed position are pushed to close
direction for 

2 seconds

 before the opening cycle begins.

DIP-SWITCH-A N°7:

ON

: Stroke reversing pulse in opening enabled 

       for 2s

OFF

: No stroke reversing pulse

7

APPLICATIONS IN BLOCKS OF FLATS:

This is a function for heavy duty applications with frequent inversions of direction: this
function, when  enabled,  takes into account the remaining motor run time when there is
an inversion of direction or passage between the photocells.

DIP-SWITCH-A N°12:

12

ON

:Memory of motor run time settings enabled

OFF

: No memory enabled

IMPORTANT: use always and only with
Dip-A N°3= ON

PARTY FUNCTION

OPEN-AND-HOLD BY EXTERNAL CLOCK:

Connection: connect the Clock NO contact to OPEN terminals
No. 4 and COMMON No. 3, and activate automatic closing by
setting Dip-Switch No. 3=ON.
How it works:  program the opening time on the clock. At the
preset time, the gates will open and remain open (the flashing
light will turn off) and will not accept any other command (not
even radio commands) until the time set on the clock expires.
When this time expires the gates close automatically after the
pause time.
While the gates are held open by the time set on the "clock",
the indication light keeps giving out two consecutive flashes
followed by a long pause.

Summary of Contents for Elpro 27

Page 1: ...igen Drehtore mit oder ohne Endschaltern und f r ein oder zweifl geligen Schiebetore max 0 5 PS mit mechanischer Kupplung D F D LIBRETTO DI ISTRUZIONI PER APRICANCELLI SCORREVOLI CON FINECORSA MONOFAS...

Page 2: ...ctions select the mode of operation depending on gate type by Dip Switch B N 1 and read the instructions respectively dedicated as follows SLIDING gates from page 13 to page 18 SWINGING gates from pag...

Page 3: ...o reversing in opening 3 ON Automatic closing 4 ON Pre flashing in service 5 ON Radio step by step 6 ON Traffic lights mode limit switches connected ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 DIP SWITCH A mecc...

Page 4: ...e L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10...

Page 5: ...8 ON 3 Set the trimmer Gate Delay in Closing to zero M1 COMMON 16 1718 19 20 21 M2 COMMON In case of 2 motors 1 Connect power supply to the terminals Motors M1 and M2 2 No gate delay in opening by Dip...

Page 6: ...e used or not in the installation Dip Switch B 3 OFF Accessory Electrical connections LED indication of functions Double sliding gate limit switches L30 ON OFF on engaging L sw Opening M1 L31 ON OFF o...

Page 7: ...the photocells after 3 seconds 4 ON DSA safety control enabled OFF DSA safety control disabled DIP SWITCH B N 4 DEADMAN HOLD ON SWITCHED FUNCTION The open close operations are achieved by holding on...

Page 8: ...n 1 OFF 12 13 12 13 24Vac output max load n 1 radio receiver n 3 pairs photocells All NC contacts of safety accessories such as Photocells receivers must be connected in series with terminals 1 and 2...

Page 9: ...L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10 9...

Page 10: ...ct power supply to the terminals Motor M1 2 No gate delay in opening by Dip A N 8 ON 3 Set the trimmer Gate Delay in Closing to zero motor delayed in closing DWELL TIME 1s 220s MOTOR RUN TIME OPEN CLO...

Page 11: ...d traffic lights Red Yellow Green 4 OFF Pre flashing Disabled traffic lights Red Green 6 ON Limit switches installed 6 OFF Limit switches linked out functioning by time setting Dip Switch B 3 ON Pre f...

Page 12: ...ic closing on passing across the photocells after 3 seconds ON 2nd pair photocells enabled OFF 2nd pair photocells not installed 9 OFF No automatic closing on passing across the photocells after 3 sec...

Page 13: ...ut by qualified technicians following Meccanica Fadini s Safety Norms Manual L installation doit tre effectu e par un technicien qualifi suivant le manuel des Normes de S curit de Meccanica Fadini Vor...

Reviews: