background image

page 15

FOR 

SLIDING GA

TE 

 SYSTEMS 

Dip-B N°1=ON

27

meccanica

FADINI

GB

27

UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz

SAFETY EDGES

JA

Accessory

Electrical connections

LED indication

L10

Normally alight

:

whenever the safety edge is engaged,
the LED goes off

JA

1 2

8,2k  Resistive

safety edge

Safety edge

in Closing:

The two inputs, that are fitted to control the safety edges, are separated for the opening and closing phases. Also, it is possible to select the type
of contact connected to them, either N.C. mechanical or 8,2 k  resistive, by means of the two jumpers JA1 or JA2.
Thanks to a dedicated microcontroller circuit separately fitted on to the board, the actual integrity and correct functioning of the safety system is
constantly controlled. Any possible fault or loss of efficiency is signalled by the L10 and L35 LEDs keeping flashing.

1 2

NC safety edge

L35

Normally alight

:

whenever the safety edge is engaged,
the LED goes off

Safety edge

in Opening:

In series if safety edges

are mechanical, N.C.

9 10

9 10

Selecting functioning:

JB

JB

1 2

Gate travel is reversed on Opening
and Closing for a short spell.

1 2

Gate travel is reversed in
Opening and Closing for
twice as much the spell.

JB

JB

1 2

Once the safety edge has been engaged and
the obstacle removed, the gate closes automatically.
(If automatic close mode has been selected).

1 2

Once the safety edge has been engaged and
the obstacle removed, the gate stays stopped
until a new pulse is given.
(Even if automatic close mode has been selected).

In parallel if safety edges

are resistive

 8,2 k

Safety edge selection:

JA

JA

1 2

8,2k  Resistive

safety edge

1 2

NC safety edge

In series if safety edges

are mechanical, N.C.

In parallel if safety edges

are resistive

 8,2 k

Safety edge selection:

32 33 34 35

32 33 34 35

8,2 k

8,2 k

(JA1 jumper)

(JA2 jumper)

(JB1 jumper)

(JB2 jumper)

Summary of Contents for Elpro 27

Page 1: ...igen Drehtore mit oder ohne Endschaltern und f r ein oder zweifl geligen Schiebetore max 0 5 PS mit mechanischer Kupplung D F D LIBRETTO DI ISTRUZIONI PER APRICANCELLI SCORREVOLI CON FINECORSA MONOFAS...

Page 2: ...ctions select the mode of operation depending on gate type by Dip Switch B N 1 and read the instructions respectively dedicated as follows SLIDING gates from page 13 to page 18 SWINGING gates from pag...

Page 3: ...o reversing in opening 3 ON Automatic closing 4 ON Pre flashing in service 5 ON Radio step by step 6 ON Traffic lights mode limit switches connected ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 DIP SWITCH A mecc...

Page 4: ...e L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10...

Page 5: ...8 ON 3 Set the trimmer Gate Delay in Closing to zero M1 COMMON 16 1718 19 20 21 M2 COMMON In case of 2 motors 1 Connect power supply to the terminals Motors M1 and M2 2 No gate delay in opening by Dip...

Page 6: ...e used or not in the installation Dip Switch B 3 OFF Accessory Electrical connections LED indication of functions Double sliding gate limit switches L30 ON OFF on engaging L sw Opening M1 L31 ON OFF o...

Page 7: ...the photocells after 3 seconds 4 ON DSA safety control enabled OFF DSA safety control disabled DIP SWITCH B N 4 DEADMAN HOLD ON SWITCHED FUNCTION The open close operations are achieved by holding on...

Page 8: ...n 1 OFF 12 13 12 13 24Vac output max load n 1 radio receiver n 3 pairs photocells All NC contacts of safety accessories such as Photocells receivers must be connected in series with terminals 1 and 2...

Page 9: ...L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10 9...

Page 10: ...ct power supply to the terminals Motor M1 2 No gate delay in opening by Dip A N 8 ON 3 Set the trimmer Gate Delay in Closing to zero motor delayed in closing DWELL TIME 1s 220s MOTOR RUN TIME OPEN CLO...

Page 11: ...d traffic lights Red Yellow Green 4 OFF Pre flashing Disabled traffic lights Red Green 6 ON Limit switches installed 6 OFF Limit switches linked out functioning by time setting Dip Switch B 3 ON Pre f...

Page 12: ...ic closing on passing across the photocells after 3 seconds ON 2nd pair photocells enabled OFF 2nd pair photocells not installed 9 OFF No automatic closing on passing across the photocells after 3 sec...

Page 13: ...ut by qualified technicians following Meccanica Fadini s Safety Norms Manual L installation doit tre effectu e par un technicien qualifi suivant le manuel des Normes de S curit de Meccanica Fadini Vor...

Reviews: