IN CASE OF FAILURE PLEASE MAKE SURE THAT

- Power supply to the electronic control box is 230V ±10%
- Power supply to the electric motor is 230V ±10%
- All of the fuses is all right
- The photocell contacts are closed
- No voltage drop has occurred from the Elpro board to the electric motor
- All of the NC contacts of the control board are all right

IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:

- The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in
  case any commercial box is used, this must be adequate to the job
- Make sure that power supply to the control board be 230V ±10%
- Make sure that power supply to the electric motor be 230V ±10%
- For distances longer than 50 metres increase the section of the wires
- Fit the mains to the control box with a high sensitivity, 0.03A, differential, magnetic-thermal circuit breaker
- Cables with 1.5mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m
- Cables with 1mm² section wires are to be used for the limit switches, photocells, push buttons and accessories
- If no photocells are used link out terminals 1 and 2
- If no stop button is used link out terminals 3 and 6
- Open/Close motor run time trimmer must be always superior to the time actually required for the gate travel
N.W.: For applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected

Diagnostic LEDs:

L ON 

= Board on 230V voltage and F1, F2, F3 fuses all right

L0 ON 

= 2

nd

 pair photocells, not obstructed

L1 ON 

= 1

st

 pair photocells not obstructed

L4 OFF 

= Open, it switches on by any open pulse

L5

 

OFF 

= Close, it switches on by any close pulse

L6

 

ON 

 = Stop, it switches off by any stop pulse

L7 OFF

 = Radio, it switches on by any pulse from the transmitter/radio contact

L8 OFF

 = Pedestrian mode, it switches on by any pedestrian pulsing

L10 ON

 = Safety edge protecting closing

L30 ON

 = It switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M1

L31

 

ON

 = It switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M1

L33 ON

 = It switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M2

L34

 

ON

 = It switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M2

L35

 

ON

 = Safety edge protecting opening

ATTENTION: before starting the electrical connections, select the mode of operation depending on gate type

by Dip Switch B N°1 and read the instructions respectively dedicated as follows:

SLIDING gates

 from page 13 to page 18 - 

SWINGING gates 

from page 19 to page 23.

!

Symbols

NC 

Contact

NO 

Contact

Led 

 ON

Led 

 OFF

Pilot light

 Flasher

27

UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz

General description:

 the electronic control box ELPRO 27 has been developed to provide a reliable unit to control single or double sliding gate automatic

systems with or without limit switches, as well as single or double swinging gate systems fitted with pressure valves. S-phase 230V 50/60Hz ELPRO 27
complies with the Low Voltage Norms 2006/95 CE and Electro-magnetic Compatibility 2004/108/CE. Installation is recommended by qualified technical
installation agents in compliance with the existing regulations. The manufacturer is not liable for any incorrect use of this appliance; and also reserves
the right to change and update it without previous notice.

ELECTRIC MOTORS

230V SINGLE-PHASE

Power supply

350W max (0.5HP)

M1

M2

F3=2A

24V low

voltage circuit

protection

F2=5A

network

F1=5A

network

COURTESY LAMP

230V MAX 100W
It goes on when gate
starts and stays  on for

a fixed time of 90

seconds

 

after motor

run time expiry

TRANSFORMER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

16 17 18 19 20 21 22 23

24

25

PLUG-IN

RADIO

CARD
CONNECTOR

2

nd

 pair

photocells

NC

1

st

 pair

photocells

radio contact

common

open

close

stop

Indication lamp 24V

max 3W

 24V

ac output

 (max

. load:

n°1 radio receiver

n°3 pairs photocells)

power supply for

electric lock

15V

A max

230Vac

 OUTPUT

max 25W for flasher

and electric latch

Control board

power supply

230V - 50/60Hz ±10%

 24V /ac output

for photocell TX

 enabling 

DS

A control

NC

common

common

NEUTRAL

LIVE

26

27

28

CARD
CONNECTOR FOR

TRAFFIC LIGHTS

(Item 7282L)

+

_

Power supply

24V - 50mA max.

DC

A

C

Selector

DC/AC

3 2 1

12V

24V

3

2

1

Pedestrian opening

LOCK
SETUP

Capacitor
 M1 Motor

12.5 µF

Capacitor
 M2 Motor

 

12.5 µF

F4=630mA

Transformer

primary

protection

OUTPUT CONFIGURATION

TERMINALS 14 - 15

UNL

ON

OFF

1 2 3 4 5 6 7 8 9 10 11 12

DIP-SWITCH - A

 

RUN 

TIME

OPEN - CLOSE

sliding: 0s - 120s

swinging: 0s - 60s

DWELL

TIME

1s - 220s

GATE DELAY

  CLOSING: 

0s - 10s

- OPENING FOR

  

PEDESTRIANS 1s - 45s

-

+

-

+

-

+

ON

OFF

1 2 3 4

DIP-SWITCH - B

ELPRO 27

UNL

E 27

L4 L5 L6 L7 L8

L10

-

+

ELECTRIC LOCK

TIME

0.5s - 20s

L30 L31 L33 L34

30 31 32 33 34

M1

M2

Fc.A.

Fc.C.

Fc.A.

Fc.C.

35

L35

JA

1 2

SETUP

EDGE

TYPE

safety edge in closing

common

JB

1 2

Safety edge

in Opening

8,2 k or NC

8,2 k

or NC

Resistive contact
8,2 k  or NC

L

L0

L1

NOTE:

The green LEDs must

always be on.

Summary of Contents for Elpro 27

Page 1: ...igen Drehtore mit oder ohne Endschaltern und f r ein oder zweifl geligen Schiebetore max 0 5 PS mit mechanischer Kupplung D F D LIBRETTO DI ISTRUZIONI PER APRICANCELLI SCORREVOLI CON FINECORSA MONOFAS...

Page 2: ...ctions select the mode of operation depending on gate type by Dip Switch B N 1 and read the instructions respectively dedicated as follows SLIDING gates from page 13 to page 18 SWINGING gates from pag...

Page 3: ...o reversing in opening 3 ON Automatic closing 4 ON Pre flashing in service 5 ON Radio step by step 6 ON Traffic lights mode limit switches connected ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 DIP SWITCH A mecc...

Page 4: ...e L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10...

Page 5: ...8 ON 3 Set the trimmer Gate Delay in Closing to zero M1 COMMON 16 1718 19 20 21 M2 COMMON In case of 2 motors 1 Connect power supply to the terminals Motors M1 and M2 2 No gate delay in opening by Dip...

Page 6: ...e used or not in the installation Dip Switch B 3 OFF Accessory Electrical connections LED indication of functions Double sliding gate limit switches L30 ON OFF on engaging L sw Opening M1 L31 ON OFF o...

Page 7: ...the photocells after 3 seconds 4 ON DSA safety control enabled OFF DSA safety control disabled DIP SWITCH B N 4 DEADMAN HOLD ON SWITCHED FUNCTION The open close operations are achieved by holding on...

Page 8: ...n 1 OFF 12 13 12 13 24Vac output max load n 1 radio receiver n 3 pairs photocells All NC contacts of safety accessories such as Photocells receivers must be connected in series with terminals 1 and 2...

Page 9: ...L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10 9...

Page 10: ...ct power supply to the terminals Motor M1 2 No gate delay in opening by Dip A N 8 ON 3 Set the trimmer Gate Delay in Closing to zero motor delayed in closing DWELL TIME 1s 220s MOTOR RUN TIME OPEN CLO...

Page 11: ...d traffic lights Red Yellow Green 4 OFF Pre flashing Disabled traffic lights Red Green 6 ON Limit switches installed 6 OFF Limit switches linked out functioning by time setting Dip Switch B 3 ON Pre f...

Page 12: ...ic closing on passing across the photocells after 3 seconds ON 2nd pair photocells enabled OFF 2nd pair photocells not installed 9 OFF No automatic closing on passing across the photocells after 3 sec...

Page 13: ...ut by qualified technicians following Meccanica Fadini s Safety Norms Manual L installation doit tre effectu e par un technicien qualifi suivant le manuel des Normes de S curit de Meccanica Fadini Vor...

Reviews: