page 18
FOR
SLIDING GA
TE
SYSTEMS
Dip-B N°1=ON
27
meccanica
FADINI
GB
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
AUTOMATIC / SEMI-AUTOMATIC:
Automatic Cycle:
by one pulse from the open command the gate opens and stops in
Dwell mode for the time as pre-set on the
Dwell Trimmer
. When this time expires the gate
closes automatically.
Semi-automatic Cycle:
by one pulse from the open command the gate opens and
stops in fully open position. To close the gate, a close pulse is needed.
Dip - Switch setting and LED indication of functions
Description
DIP-SWITCH-A N°9 and N°11:
PEDESTRIAN OPENING:
With the gate in fully closed position, a pulse to terminals
3-8 operates the gate for pedestrians.
(On pedestrian mode, it is advisable to set Dip-A N°3= ON
for automatic re-closing).
The function "
Pedestrian Opening
" is not in service during
the first operation cycle, after a power failure.
FUNCTIONS FOR SLIDING GATE OPENING - Dip Switch B n°1=ON
RE-CLOSING BY PASSING ACROSS THE PHOTOCELLS: in opening and dwell cycles
(DIP-A N°3=ON)
Gate is automatically closed after 3s from passing between the photocells.
In case a second pair of photocells are installed, (Dip 9=ON), both pairs are to be
passed across.
Dwell Trimmer:
adjust dwell time
on automatic mode
from 1s up to 220s
3
ON
: Automatic closing
DIP-SWITCH-A N°3:
-
+
L8 OFF
= no pedestrian contact given,
it goes on by pulsing for pedestrians
OPEN
PEDESTRIANS
11
ON
: Automatic closing on passing across
the photocells after 3 seconds
ON
: 2
nd
pair photocells enabled
OFF
: 2
nd
pair photocells not installed
9
OFF
: No automatic closing on passing across
the photocells after 3 seconds
4
ON
: DSA safety control enabled
OFF
: DSA safety control disabled
DIP-SWITCH-B N°4:
DEADMAN (HOLD-ON-SWITCHED) FUNCTION:
The open/close operations are achieved by "holding on a command switched" (the
relays are not self-holding) and consequently the user must be actively present during
gate movements until the push-button or the key-switch is released.
2
ON
: Deadman control enabled
OFF
: Deadman control disabled
DIP-SWITCH-B N°2:
COMMON
NO
External time clock
3
ON
: Automatic closing
DIP-SWITCH-A N°3:
3 4
OPEN
COMMON
24V ac Output
for photocell
transmitter TX
enabled for
DSA control
IMPORTANT: use always and only with
Dip-A N°3= ON
PARTY FUNCTION
OPEN-AND-HOLD BY EXTERNAL CLOCK:
Connection: connect the Clock NO contact to OPEN
terminals No. 4 and COMMON No. 3, and activate
automatic closing by Dip-Switch No. 3=ON.
How it works: program the opening time on the clock.
At the preset time, the gate will open and remain open
(the flashing light will turn off) and will not accept any
other command (not even radio commands) until the
time set on the clock expires. When this time expires
the gate closes automatically after the pause time.
While the gate is held open by the time set on the
"clock", the indication light keeps giving out two
consecutive flashes followed by a long pause.
DSA: PHOTOCELL AUTOMATIC CONTROL:
For the
DSA
control (
D
evice for
S
afety
A
uto-test) it is necessary
to connect
only the photocell transmitters (TX)
to this output
and select
Dip-B No.4=ON:
if this function is enabled, ELPRO 27
checks that all the connected photocell devices are cleared
from obstacles and properly working before starting any
door/gate movements, otherwise the door/gate is not started.
OFF
: Semi-automatic, closing by pulse
-
+
OPENING FOR
PEDESTRIANS
1s - 45s
RIT. C
3 4 5 6 7 8
16
15