Programmatore elettronico con condensatori motore incorporati; idoneo per
cancelli battenti a una o due ante, con o senza finecorsa e per cancelli
scorrevoli a una o due ante (max. 0,5 CV con frizione meccanica).

Via Mantova 177/A - 37053 Cerea (VR) Italy
Tel. +39 0442 330422 r.a. - Fax. +39 0442 331054
e-mail: [email protected]   -   www.fadini.net

Electronic control box with incorporated motor capacitors; suitable for
oil-hydraulic, single or double swinging gates, with or without limit switches and
for single or double sliding gates (max. 0.5 HP with mechanical clutch).

I

GB

I

GB

I

Programmateur électronique avec condensateurs moteur incorporé; adapté pour
ouvre-portails a battant avec 1 ou 2 vantaux, avec ou sans fin de course et pour
ouvre-portail coulissants avec 1 ou 2 vantaux (max. 0,5 CV avec embrayage mécanique).

F

Elektronische Steueurung mit eingebauten Motor-Kondensatoren; geeignet für
ein-oder zweiflügeligen Drehtore, mit oder ohne Endschaltern und für ein-oder
zweiflügeligen Schiebetore (max. 0,5 PS mit mechanischer Kupplung).

D

F

D

LIBRETTO DI ISTRUZIONI

PER APRICANCELLI 

SCORREVOLI CON FINECORSA 

MONOFASE 230V 50/60Hz

A 1 O 2 ANTE 

pag. 2, 3, 4, 5, 6, 7

INSTRUCTIONS MANUAL

FOR 

SLIDING

 GATE OPERATORS 

WITH LIMIT SWITCHES

, S-PHASE 230V 50/60Hz

SINGLE or DOUBLE GATES 

pages 13, 14, 15, 16, 17, 18

NOTICES D'INSTRUCTIONS

POUR OUVRE-PORTAILS 

COULISSANTS AVEC FINS DE COURSE 

MONOPHASE 230V 50/60Hz

AVEC 1 OU 2 VANTAUX 

pages 24, 25, 26, 27, 28, 29

BETRIEBSANLEITUNG

FÜR 

SCHIEBETORANTRIEBE MIT ENDSCHALTERN, 

EINPHASIG 230V 50/60Hz,

MIT EINEM ODER ZWEI TORFLÜGELN 

Seite 35, 36, 37, 38, 39, 40

F

D

LIBRETTO DI ISTRUZIONI

PER APRICANCELLI A 

BATTENTE OLEODINAMICI 

MONOFASE 230V 50/60Hz

A 1 O 2 ANTE 

pag. 2, 8, 9, 10, 11, 12

INSTRUCTIONS MANUAL

FOR 

OIL-HYDRAULIC SWINGING 

ACTUATORS, S-PHASE 230V 50/60Hz

SINGLE or DOUBLE GATES 

pages 13, 19, 20, 21, 22, 23

NOTICES D'INSTRUCTIONS

POUR OUVRE-PORTAILS A 

BATTANT HYDRAULIQUES 

MONOPHASE 230V 50/60Hz

AVEC 1 OU 2 VANTAUX 

pages 24, 30, 31, 32, 33, 34

BETRIEBSANLEITUNG

FÜR 

ÖLHYDRAULISCHE DREHTOR

ANTRIEBE

 

EINPHASIG 230V 50/60Hz

MIT EINEM ODER ZWEI TORFLÜGELN

 

Seite 35, 41, 42, 43, 44, 45

Summary of Contents for Elpro 27

Page 1: ...igen Drehtore mit oder ohne Endschaltern und f r ein oder zweifl geligen Schiebetore max 0 5 PS mit mechanischer Kupplung D F D LIBRETTO DI ISTRUZIONI PER APRICANCELLI SCORREVOLI CON FINECORSA MONOFAS...

Page 2: ...ctions select the mode of operation depending on gate type by Dip Switch B N 1 and read the instructions respectively dedicated as follows SLIDING gates from page 13 to page 18 SWINGING gates from pag...

Page 3: ...o reversing in opening 3 ON Automatic closing 4 ON Pre flashing in service 5 ON Radio step by step 6 ON Traffic lights mode limit switches connected ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 DIP SWITCH A mecc...

Page 4: ...e L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10...

Page 5: ...8 ON 3 Set the trimmer Gate Delay in Closing to zero M1 COMMON 16 1718 19 20 21 M2 COMMON In case of 2 motors 1 Connect power supply to the terminals Motors M1 and M2 2 No gate delay in opening by Dip...

Page 6: ...e used or not in the installation Dip Switch B 3 OFF Accessory Electrical connections LED indication of functions Double sliding gate limit switches L30 ON OFF on engaging L sw Opening M1 L31 ON OFF o...

Page 7: ...the photocells after 3 seconds 4 ON DSA safety control enabled OFF DSA safety control disabled DIP SWITCH B N 4 DEADMAN HOLD ON SWITCHED FUNCTION The open close operations are achieved by holding on...

Page 8: ...n 1 OFF 12 13 12 13 24Vac output max load n 1 radio receiver n 3 pairs photocells All NC contacts of safety accessories such as Photocells receivers must be connected in series with terminals 1 and 2...

Page 9: ...L10 and L35 LEDs keeping flashing 1 2 NC safety edge L35 Normally alight whenever the safety edge is engaged the LED goes off Safety edge in Opening In series if safety edges are mechanical N C 9 10 9...

Page 10: ...ct power supply to the terminals Motor M1 2 No gate delay in opening by Dip A N 8 ON 3 Set the trimmer Gate Delay in Closing to zero motor delayed in closing DWELL TIME 1s 220s MOTOR RUN TIME OPEN CLO...

Page 11: ...d traffic lights Red Yellow Green 4 OFF Pre flashing Disabled traffic lights Red Green 6 ON Limit switches installed 6 OFF Limit switches linked out functioning by time setting Dip Switch B 3 ON Pre f...

Page 12: ...ic closing on passing across the photocells after 3 seconds ON 2nd pair photocells enabled OFF 2nd pair photocells not installed 9 OFF No automatic closing on passing across the photocells after 3 sec...

Page 13: ...ut by qualified technicians following Meccanica Fadini s Safety Norms Manual L installation doit tre effectu e par un technicien qualifi suivant le manuel des Normes de S curit de Meccanica Fadini Vor...

Reviews: