Min.
28 mm
min.
100
mm
55
mm
max.
R 5 mm
520 mm
780 mm
min.
500
mm
490+2
mm
mm
750
+2
FCH 84 BK KL – FCH 84 GR KL
• For further information on the installa-
tion, please refer to the Assembly In-
structions.
• If there is no oven beneath the hob, in-
stall a separation panel under the ap-
pliance according to the Assembly In-
structions.
3. ELECTRICAL
CONNECTIONS
WARNING:
All electrical connec-
tions must be carried out by an au-
thorised installer.
• Before making the connections, check
that the rated voltage of the appliance
indicated on the relevant rating plate
corresponds to the power supply
voltage. The rating plate is affixed to
the underside of the hob.
• Follow the connection diagram (loc-
ated on the underside of the hob).
• Only use original components sup-
plied by the spare parts service.
• The appliance is supplied with a
power cable.
• If damaged, replace the power supply
cables with original spare cables.
Contact the After Sales Service.
Caution!
Do not weld any of the
cables!
Electrical connection
• The wire connection must be per-
formed by a specialised technician.
• This device has a Y-shaped connec-
tion with an H05V2V2-F cable. Min.
wire section: 5x2.5 mm².
• Connection terminals can be ac-
cessed by removing junction box
cover.
• Make sure the specifications of the
household electrical system (voltage,
maximum power and current) are
compatible with those of the appli-
ance.
• Connect the appliance as shown in
the diagram (in accordance with the
mains voltage and country standard
reference).
Connection diagram
220V - 240V 1N
N
L
L
Black
L
Brown
N
Blue
N
Grey
Yellow / Green
6
Summary of Contents for FCH 84 GR
Page 2: ...EN 3 FR 19 IT 37 RU 53 ES 71 DE 88 NL 105 AL 122 MK 139 SR 157...
Page 53: ...RU 1 I 53...
Page 54: ...8 8 54...
Page 55: ...3 III 55...
Page 59: ...Art Cod SN 59...
Page 61: ...6 1 5 4 2 8 6 7 3 A 1 2 3 4 5 6 7 8 A 4 7 1 61...
Page 62: ...2 3 1 2 4 3 8 0 7 4 1 6 2 5 3 4 4 3 5 5 3 6 2 5 8 3 3 4 0 9 10 4 3 9 0 10 1 62...
Page 63: ...Boost 5 4 P 3 0 0 0 10 3 0 0 0 3 0 0 0 10 0 0 0 4 63...
Page 64: ...1 48 2 144 3 230 4 312 5 408 6 120 7 168 8 216 9 P 1 8 3 A 3 10 1 1 10 6 6 2 2 U9 9 1 2 3 64...
Page 65: ...4 5 6 7 8 9 P 10 3 4 3 1 2 2 9 2 1 U2 0 1 3 U3 0 1 3 U4 0 9 U5 0 1 U6 0 1 65...
Page 67: ...110 200 110 145 110 190 110 190 13 ER03 10 ER21 E2 67...
Page 70: ...17 66 2014 EN IEC 60350 2 EN IEC 50564 70...
Page 121: ...De technische gegevens staan op het typeplaatje aan de onderkant van het product 121...
Page 139: ...MK 1 I 139...
Page 140: ...8 8 140...
Page 141: ...3 mm III e 141...
Page 143: ...3 Y H05V2V2 F 5x2 5 mm 220V 240V 1N N L L L N N 143...
Page 145: ...e S N 5 145...
Page 147: ...6 1 5 4 2 8 6 7 3 A 1 2 3 4 5 6 7 8 A 4 7 147...
Page 148: ...1 2 3 1 2 4 3 8 KW 0 7 4 1 6 2 5 3 4 4 3 5 5 3 6 2 5 8 3 3 4 0 9 10 3 4 9 0 10 1 148...
Page 149: ...5 4 P 3 0 0 0 10 3 0 0 0 3 0 0 0 10 0 0 0 4 149...
Page 150: ...1 48 2 144 3 230 4 312 5 408 6 120 7 168 8 216 9 P 3 1 8 3 10 1 1 10 6 6 U9 9 1 2 3 150...
Page 151: ...4 5 6 7 8 9 P 10 3 4 3 1 2 2 9 2 1 U2 0 1 3 U3 0 1 3 U4 0 9 U5 0 1 U6 0 1 151...
Page 153: ...110 mm 200 mm 110 mm 145 mm 110 mm 190 mm 110 mm 190 mm 13 ER03 10 ER21 E2 153...
Page 156: ...a 17 66 2014 EN IEC 60350 2 EN IEC 50564 156...
Page 157: ...SR 1 1 157...
Page 158: ...8 8 158...
Page 159: ...3 3 2 159...
Page 164: ...6 1 5 4 2 8 6 7 3 A 1 2 3 4 5 6 7 8 A 4 7 164...
Page 165: ...1 2 3 1 2 4 3 8 kW 0 7 4 1 6 2 5 3 4 4 3 5 5 3 6 2 5 8 3 3 4 0 9 10 3 4 9 0 10 1 5 4 165...
Page 166: ...0 0 0 10 3 0 0 0 0 0 0 10 0 0 0 4 166...
Page 168: ...7 8 9 10 3 4 3 1 2 2 9 2 1 U2 0 1 3 U3 0 1 3 U4 0 9 U5 0 1 U6 0 1 U7 0 1 2 168...
Page 170: ...110 200 110 145 110 190 110 190 13 ER03 10 ER21 E2 E3 8 E6 170...
Page 173: ......
Page 174: ......
Page 175: ......