background image

23

11.3

Connection of MINIDEC, RP cards

Insert the MINIDEC or RP decoding card in the block connector
J5 (Fig. 7), with the components facing up (Fig. 7 shows the
connection of cards RP433DS).
For programming the decoding cards, consult the individual
instructions.

Mains power present and battery charged.

Mains power not supplied for not more
than 5 minutes, with battery charged.

When mains power returns, the LED stays
lighted steadily.

If mains power is still not supplied, the LED
goes off (SLEEP mode).

Mains power present and battery
discharged (

gate locked).

The LED continues to flash rapidly until the
battery has recharged sufficiently.

If mains power is not supplied, the LED goes
off (SLEEP mode).

No mains power supplied (SLEEP mode).

Steady light

Slow flashing
(lights every
second)

Rapid flashing
(lights every 250
msec)

Light OFF

Tab. 2

 - Description of LED P status

12.1

Powering up the system

After making all the cable connections we described previously,
power up the system to enable diagnostics, check of inputs
status and programming.

12.

START-UP

When the LEDs light up, this indicates the inputs status as shown
in Tab. 3.

12.3     Status of inputs

The MASTER-B board has a function for checking the status of
inputs on the terminal board.
In all LEDS OFF status (LEDs both with letters and numbers), press
the P2 push-button.

12.2     Diagnostics

LED "P" (see Fig.7) - visible from outside the enclosure - performs
the diagnostics function. The LED has 4 statuses:

Note:

in the SLEEP mode, an OPEN pulse is sufficient to move
the gate (with charged battery)

Fig. 7

t

12.4     Programming

These are the basic settings of the MASTER-B board:

MASTER-B board

LEAF 1

Function logic:

A4

Pause times:

B1

Opening/closing delay:

C3

Static force:

D3

Speed:

E2

If you wish to execute customised programming (see par. from
12.4.1 to 12.4.6) and time-learning  (see par.12.4.7 and 12.4.8)
follow the steps in the next pages.

 

   

LEDs

Lighted

Off

(closed contact)

(open contact)

A = Open A

Command active

Command inactive

B = Open B

Command active

Command inactive

C = Stop

Command inactive

Command active

D = Fsw op

Safety devices disengaged

Safety devices engaged

E = Fsw cl

Safety devices disengaged

Safety devices engaged

1 = SLAVE-B

SLAVE-B present

SLAVE-B absent

and active

or inactive

Tab. 3

 - Description of inputs status LEDs

P1

P2

Notes

:

The status of LEDs with the gate closed at rest is shown in

bold

.

LED 1 is active only when the MASTER-B and SLAVE-B boards
communicate in systems with double-leaf gates and with
the SLAVE-B battery charged.

In the inputs status function, push-button P1 commands an
OPEN A.

When checks have finished, once again press push-button P2
to exit the inputs status function.

Summary of Contents for MASTER-B

Page 1: ...TER B SLAVE B carta riciclata 100 per la natura for nature recycled paper 100 ist umweltfreundlich 100 Altpapier para la naturaleza 100 papel reciclado papier recycl 100 pour la nature voor de natuur...

Page 2: ...the essential safety requirements of the following EEC directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 EEC and 93 68 EEC and also declares that it is...

Page 3: ...erations and run the functional checks HOW TO CHARGE THE BATTERIES FOR THE FIRST TIME Charging can be done directly at the bench before the system is installed Follow the instructions referring to the...

Page 4: ...when opening and closing op 0s cl 0s op 2s cl 2s op 2s cl 4s op 2s cl 8s Speed Selectable on 4 levels Static force adjustment Selectable on 4 levels Terminal board inputs Open Open released leaf Stop...

Page 5: ...lay electric cables use adequate rigid and or flexible tubes 2 To avoid any kind of interference always separate low voltage connection cables from 230Vac power cables 3 The transformer can be remotel...

Page 6: ...accessories and pulse generators will be connected and the SLAVE B units near the DOMO operators using 4 expansion bolts and their fixing screws Route the electric cables to the bottom of the box usi...

Page 7: ...fuse F20A J1 Accessories terminal board J2 Transformer terminal board J3 Motor connection terminal board J4 Battery connector J5 Minidec RP Receiver connector 10 MASTER B BOARD LAYOUT F1 Battery and...

Page 8: ...Opening safety devices contact Photocells e g SAFEBEAM 1 5 FSW CL Closing safety devices contact Photocells e g SAFEBEAM 1 6 BUS MASTER B SLAVE B connection 7 8 positive for 24V power supply Accessori...

Page 9: ...ontact have the same function they must be connected to each other in series Fig 10 Connection of 2 NA contacts in parallel Fig 11 N B If two or more devices with N A contact have the same function th...

Page 10: ...board In all LEDS OFF status LEDs both with letters and numbers press the P2 push button 12 2 Diagnostics LED P see Fig 7 visible from outside the enclosure performs the diagnostics function The LED h...

Page 11: ...A1 automatic A2 safety A3 Step by step automatic A4 Step by step semi automatic default Press push button P1 again and LED B will light together with LED 1 12 4 3 Pause Times Press push button P2 for...

Page 12: ...ke sure that the gate is closed and operators locked 12 4 8 Complete learning If you press push button P2 for more than 3 seconds leaf 1 begins to move You can command the following functions with sub...

Page 13: ...ight If you wish to use a 12V 0 5W indicator light terminal 9 11 of J1 see Fig 8 the following table shows the statuses of the indicator light according to gate position Tab 4 Statuses of indicator li...

Page 14: ...ING SAFETY DEVICES STOP PULSES Table 5 c CLOSED Opens leaf ves and re closes after pause time No effect OPEN disabled No effect OPENING Reloads pause time Immediately reverses to open No effect Stops...

Page 15: ...ery fuses failed Check the fuses F20A and if necessary replace them No mains power supplied for more than 24 hours The radio receiver is re activated when mains power returns or by giving a pulse with...

Page 16: ...ppen van de apparaat gehandhaafd blijven zonder zich daardoor te verplichten deze publicatie bij te werken Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sello del Rev...