![FAAC MASTER-B Manual Download Page 11](http://html1.mh-extra.com/html/faac/master-b/master-b_manual_3122080011.webp)
24
t
MASTER-B commands leaf 1
(Default).
MASTER-B commands leaf 2
P1
P2
t
P1
P2
t
In all LEDs OFF status, press and
hold down push-button P1, and
press push-button P2 - LED A begins
to flash.
Using push-button P2, move from LED 1 to LED 2 according to
the type of leaf management you require, as described below.
12.4.1 Leaf 1 management with MASTER-B or SLAVE-
B board
P1
P2
t
t
Press push-button P1 again to exit.
P1
P2
t
In all LEDS OFF status, press push-
button P1.
Led
A
will light up together with
LED
4
.
12.4.2 Function Logic
P1
P2
t
P1
P2
t
Press push-button P2, for a choice
of 4 different function logics.
A1
automatic
A2
safety
A3
Step-by-step automatic
A4
Step-by-step semi-automatic
(default)
ÜÜ
Press push-button P1 again and
LED
B
will light together with LED
1
.
12.4.3 Pause Times
Press push-button P2, for a choice
of 4 different pausetimes.
B1
5 seconds (default)
B2
10 seconds
B3
20 seconds
B4
30 seconds
P1
P2
t
P1
P2
ÜÜ
Press push-button P1 again and
LED
C
will light together with LED
3
.
12.4.4 Opening/Closing Delay
Press push-button P2, for a choice
of 4 different delays.
C1
op. 0 sec / cl. 0 sec
C2
op. 2 sec / cl. 2 sec
C3
op. 2 sec / cl. 4 sec (default)
C4
op. 2 sec / cl. 8 sec
P1
P2
t
ÜÜ
P1
P2
t
Press push-button P1 again and
LED
D
will light together with LED
3
.
12.4.5 Static Force
Press push-button P2, for a choice
of 4 different static forces.
D1
low
D2
medium low
D3
medium high (default)
D4
high
P1
P2
t
P1
P2
t
ÜÜ